Highly Flexible Installation and Design (ME2 Series)

Image: 2-Way Cooling or Heating FSV-EX ME2 Series / 2-Way Cooling Only FSV-EX MS3 Series and pictures of the product in use

Highly Flexible Installation and Design

2-Pipe FSV-EX ME2 Series

The FSV-EX ME2 Series has superior installation capability and can be installed in a variety of arrangements.
This flexibility is advantageous not just during installation but also in terms of maintenance and repairs.

Increased Piping Length for Greater Design Flexibility

Adaptable to various building types and sizes
Actual piping length: 200 m
Maximum piping length: 1,000 m

* Elevation difference of Max. 90 m in case of ODU is higher than IDU may be allowed following certain conditions. Please consult with Panasonic sales engineers in case of piping elevation of over 50 m is required.

Image: Increased Piping Length for Greater Design Flexibility

Up to 50 m Length Difference Between the Longest and the Shortest Piping from the First Branch

Up to 50 m length difference between the longest and the shortest piping from the first branch. The flexible piping layout makes it easier to design systems for locations such as train stations, airports, schools, and hospitals.

Image: Up to 50 m Length Difference Between the Longest and the Shortest Piping from the First Branch

Up to 64 Units Connectable

Up to 64 indoor units can be connected in a single system for ultimate design flexibility.

Note: Maximum number of indoor units depends on outdoor unit capacity.

Image: Up to 64 Units Connectable

Connectable Indoor/Outdoor Unit Capacity Ratio Up to 130%

FSV systems attain a maximum indoor unit connection capacity of up to 130%* of the unit’s connection range, depending on the outdoor and indoor models selected. So for a reasonable investment, FSV systems provide an ideal air conditioning solution for locations where full cooling/heating is not always required.

*If the following conditions are satisfied, the effective range is above 130% up to 200%.
 (1) Obey the limited number of connectable indoor units.
 (2) The lower limit of operating range for heating outdoor temperature is limited to -10°CWB (standard -25°CWB).
 (3) Simultaneous operation is limited to less than 130% of connectable indoor units.

Note: If more than 100% indoor units are operated with a high load, the units may not perform at the rated capacity. For the details, please consult with an authorised Panasonic dealer.
MNcIU : Maximum Number of Connectable Indoor Unit

Image: Table of Connectable Indoor/Outdoor Unit Capacity Ratio

Compact Design Enables Conveyance by Lift

22.4 - 28.0 kW are able to fit inside a lift for easy handling on site.

Image: Compact Design Enables Conveyance by Lift

High External Static Pressure Allows Installation on Every Floor of a Building

With a newly designed fan, fan guard, motor, and casing, new models can be custom-installed on site to provide up to 80 Pa of external static pressure. An air discharge duct prevents shortages of air circulation, allowing the installation of outdoor units on every floor and compatibility with high-rise buildings.

Image: High External Static Pressure Allows Installation on Every Floor of a Building