Advanced Purification Model with Ultrafiltration (UF) Membrane
Features
Effects of the Water Generated by Alkaline Ionizer
For a Healthier Stomach
- Alleviates feeling of heaviness or discomfort in stomach
- Helps gastrointestinal movement for favorable bowel movements
Effectively Supports Daily Cooking
For Washing Your Face
What is the Alkaline Ionizer ?
Generates 7 Kinds of Water to Support Your Life
(pH 3.0 water, which is useful for washing items and removing tea stains in cups, is output from the acidic water stand when Alkaline 4 is selected and the faucet is turned to reduce water flow.)
How Is Ionized Water Generated?
Thoroughly Filtered, Pure,
Worry-free Water
4-stage Purification System
We Use NSF42 Certified Activated Carbon
Thorough Purification Performance
Bromodichloromethane/Dibromochloromethane/Chloroform/Bromoform/Tetrachloroethylene/
Trichloroethylene/1,1,1- Trichloroethane/CAT (agricultural chemicals)/2-MIB (mold odor)/Soluble lead
At a Glance Operation with Control Panel
Convenient Features
Water Switching Lever with Hot Water Guard
Acidic Water Stand
Japanese Quality & Reliability
Get Inspired
Specs
Size and Weight
- Height
- 318mm
- Width
- 200mm
- Depth
- 123mm
- Weight
- 4.1kg
*Main unit **Approx. 4.6 kg when full of water
- AlCare
- Made in Japan
- NSF Certified
- HALAL Certified
Generates 7 Kinds of Water: 4 Levels Alkaline, Purified, 2 Levels Acidic
Ionized Water Output Volume 1.2 L/min. at 100 kPa Water Pressure
Alkaline ionized water is safe to drink, improves gastrointestinal function, and can be used effectively for cooking.
Purified Water Output Volume 1.6 L/min. at 100 kPa Water Pressure
Advanced Water Purification with Ultrafiltration Membrane Removes Viruses and 99.999% of Bacteria
High Performance 4-stage Filtration Removes Harmful Substances: JIS 13 + JWPA 4 Substances
Rating
-
220-240 V ~ , 50 Hz, 0.8 A
Power Consumption
-
Approx. 130 W (approx. 1 W during standby)
Temperature of Water Used by Alkaline Ionizer
-
Under 35 ℃ (under 80 ℃ for bypass selector)
Pressure of Water Used by Alkaline Ionizer (dynamic pressure)
-
70 kPa to 350 kPa
Usable Water Service Pressure (static pressure)
-
70 kPa to 750 kPa
Purified Water Output Volume
-
1.6 L/min. (at 100 kPa water pressure)
Filtration Flow Volume
-
1.6 L/min. (at 100 kPa water pressure)
Cartridge Installed in the Unit
-
TK-AS65C1-EX
Guide for Time to Replace Cartridge
-
Approx. 1 year (Note 6)
Filter Material
-
Non-woven fabric, granular activated carbon, ceramic, powdered activated carbon, hollow fi ber membrane
Components which cannot be Filtered Out
-
Iron dissolved in water, heavy metals (silver, copper, etc.), salt (seawater)
Length of Power Cord
-
Approx. 3 m
Power Protection Device
-
Current fuse: 2.5 A
Overheating Protection Devices (inside isolation transformer)
-
Overheating protector (automatic resetting type, activated at temperature of 120 ℃) Thermal fuse (activated at temperature of 145 ℃) × 1
NOTES
-
1. All figures given are for a water temperature of 20 ℃.
2. This product cannot convert hard water into soft water.
3. The total volume of water coming out of the main spout, acidic water spout and drain outlet is given as the run through water volume and daily volume of water used.
(Note 1): The water which can be used as alkaline ion water and weak acidic water is equivalent to about 80% of the filtration flow volume.
(Note 2): This period may be shorter depending on the water quality and usage environment.
(Note 3): This value is for a removal rate of 80% based on JIS S 3201 tests.
(Note 4): This value is for a fi ltration flow volume of 50% based on JIS S 3201 tests.
(Note 5): This value is for a removal rate of 80% based on specifi cation standard tests (JWPAS B standards) stipulated by the Japan Water Purifier Association (JWPA).
Note that the removal of iron (particulate form) and aluminum (neutral) are not stipulated as part of purifi cation capacity.
(Note 6): This period applies when 15 liters of water are used a day. If 30 liters are used a day, the cartridge usage limit will be approximately one-half.
The period may also be signifi cantly less depending on the amount of water used and on its quality and pressure.
Main Unit
-
Dimensions (WxDxH)
-
Approx. 200 x 123 x 318 mm
-
-
Weight
-
Approx. 4.1 kg (approx. 4.6 kg when full of water)
-
Electrolysis
-
Electrolysis Method
-
Continuous electrolysis
-
-
Output Water Volume (flow of water produced)
-
1.2 L/min. (at 100 kPa water pressure)
2.5 L/min. (at 200 kPa water pressure)
-
-
Electrolysis Capability Selection
-
Alkaline: 4 levels; weak acidic: 2 levels
-
-
Continuous Operation Capability
-
Approx. 30 minutes at room temperature (approx. 10 minutes for Stronger at Alkaline 3 (Drinking water in daily life), Alkaline 4 capability (Strongly Alkaline), Weak Acidic) (Note 2)
-
-
Electrolyzer Life
-
Approx. 850 hours cumulative (ion water production time, cleaning time only)
-
-
Electrolytic Cleaning
-
Auto cleaning method (cleaning time: approx. 35 seconds, waste water drain time: approx. 15 seconds)
-
Purification Capacity (Note 1)
-
Free Residual Chlorine
-
6000 L (Note 3)
-
-
Turbidity
-
6000 L (Note 4)
-
-
Total Trihalomethane
-
6000 L (Note 3)
-
-
Chloroform
-
6000 L (Note 3)
-
-
Bromodichloromethane
-
6000 L (Note 3)
-
-
Dibromochloromethane
-
6000 L (Note 3)
-
-
Bromoform
-
6000 L (Note 3)
-
-
Tetrachloroethylene
-
6000 L (Note 3)
-
-
Trichloroethylene
-
6000 L (Note 3)
-
-
1,1,1-Trichloroethane
-
6000 L (Note 3)
-
-
CAT
-
6000 L (Note 3)
-
-
2-MIB (mold smell)
-
6000 L (Note 3)
-
-
Soluble Lead
-
6000 L (Note 3)
-
Substances Other than Above that Can be Removed
-
Iron (particulate form)
-
Can be removed (Note 5)
-
-
Aluminium (neutral)
-
Can be removed (Note 5)
-
-
Geosmin (mold smell)
-
6000 L (Note 5)
-
-
Phenols
-
6000 L (Note 6)
-