Retail Sales Price: Panasonic Online Price: SHOP NOW SHOP NOW WHERE TO BUY Buy from Panasonic Where to Buy Out of Stock at Panasonic Online false false false

R32 Non-Inverter Fresh Series Ceiling Ducted

SHOP NOW

R32 Non-Inverter Fresh Series Ceiling Ducted

A slim-type model with a interchangeable air intake that remains concealed in the ceiling

R32 Non-Inverter Fresh Series Ceiling Ducted units are suitable for premises with concealed or false ceilings, such as business centers. The rear air intake is standard.
  • Fresh Series
  • R32
Zoom In
Zoom Out
Close
R32 Non-Inverter Fresh Series Ceiling Ducted

Features

Btu/h (rated)

18,000

24,000

30,000

36,000

48,000

60,000

Phase

1Ø Phase

1Ø Phase

1Ø Phase

3Ø Phase

3Ø Phase

3Ø Phase

Indoor Unit

S-18PFB1H5B

S-24PFB1H5B

S-30PFB1H5B

S-36PFB1H5B

S-48PFB1H5B

S-60PFB1H5B

Outdoor Unit

U-18PNB1H5

U-24PNB1H5

U-30PNB1H5

U-36PNB1H8

U-48PNB1H8

U-60PNB1H8

Enables Air Conditioning Without Disturbing Quiet Spaces

Features a low sound pressure level of 28 dB(A), as quiet as that of rustling leaves. It is ideal for quiet and relaxing spaces, such as hotel lobbies and guest rooms, thanks to its superior quiet performance.
Enables Air Conditioning Without Disturbing Quiet Spaces

Precise Control, Easy Comfort

Panasonic Fresh Series remote controllers are designed with user convenience in mind. Multiple settings are available so airflow and air quality can be regulated according to preferences.
Precise Control, Easy Comfort

Compact Outdoor Unit

Compact outdoor units are built to be compact with versatile piping and draining methods and offer side-by-side installation capability.
Compact Outdoor Unit

Easily Installed in Limited Spaces

The unit has a height of only 200 mm*, so it allows installation in limited ceiling spaces. The lightweight, attractive design simplifies installation and matches virtually all room interiors.
*200 mm: S-18PFB1H5B, 245 m: S-24PFB1H5B, S-30PFB1H5B, S-36PFB1H5B, S-48PFB1H5B, S-60PFB1H5B
Easily Installed in Limited Spaces

Specs

S-18PFB1H5B_U-18PNB1H5

Photo of S-18PFB1H5B_U-18PNB1H5

S-24PFB1H5B_U-24PNB1H5

Photo of S-24PFB1H5B_U-24PNB1H5

S-30PFB1H5B_U-30PNB1H5

Photo of S-30PFB1H5B_U-30PNB1H5

S-36PFB1H5B_U-36PNB1H8

Photo of S-36PFB1H5B_U-36PNB1H8

S-48PFB1H5B_U-48PNB1H8

Photo of S-48PFB1H5B_U-48PNB1H8

S-60PFB1H5B_U-60PNB1H8

Photo of S-60PFB1H5B_U-60PNB1H8
  • Fresh SeriesFresh Series
  • R32R32

Interchangeable air intake

The slim design makes height only 200-245 mm

Precise control, easy comfort

Wired remote controller included

S-18PFB1H5B_U-18PNB1H5 S-24PFB1H5B_U-24PNB1H5 S-30PFB1H5B_U-30PNB1H5 S-36PFB1H5B_U-36PNB1H8 S-48PFB1H5B_U-48PNB1H8 S-60PFB1H5B_U-60PNB1H8
Power Source 220-240 V, 1 phase - 50 Hz 220-240 V, 1 phase - 50 Hz 220-240 V, 1 phase - 50 Hz 380-415 V, 3 phase - 50 Hz 380-415 V, 3 phase - 50 Hz 380-415 V, 3 phase - 50 Hz
Indoor S-18PFB1H5B S-24PFB1H5B S-30PFB1H5B S-36PFB1H5B S-48PFB1H5B S-60PFB1H5B
Outdoor U-18PNB1H5 U-24PNB1H5 U-30PNB1H5 U-36PNB1H8 U-48PNB1H8 U-60PNB1H8
Cooling Capacity: Rated 5.28 kW, 18,000 Btu/h 7.03 kW, 24,000 Btu/h 8.79 kW, 30,000 Btu/h 10.55 kW, 36,000 Btu/h 14.07 kW, 48,000 Btu/h 17.58 kW, 60,000 Btu/h
Current 8.00 A 10.40 A 12.50 A 6.69 A 8.35 A 10.00 A
Power Input: Rated 1.73 kW 2.34 kW 2.74 kW 3.6 kW 4.67 kW 5.71 kW
COP/EER 3.05 W/W, 10.41 Btu/hW 3.00 W/W, 10.24 Btu/hW 3.21 W/W, 10.95 Btu/hW 2.93 W/W, 10.00 Btu/hW 3.01 W/W, 10.27 Btu/hW 3.08 W/W, 10.51 Btu/hW
External Static Pressure 50 Pa 50 Pa 50 Pa 50 Pa 80 Pa 80 Pa
Indoor Unit: Air Volume (Hi/Mi/Lo) 15/12.4/7.91 m³/min, 530/438/279 cfm 20.6/18.3/16.5 m³/min, 727/646/583 cfm 24.8/21.8/20.8 m³/min, 876/770/735 cfm 24.8/21.8/20.8 m³/min, 876/770/735 cfm 32.1/27.1/24.3 m³/min, 1,134/957/858 cfm 32.1/27.1/24.3 m³/min, 1,134/957/858 cfm
Indoor Unit: Sound Pressure Level (Hi/Mi/Lo) 35/31/28 dB (A) 39/36/33 dB (A) 41/38/35 dB (A) 41/38/35 dB (A) 44/43/39 dB (A) 44/43/39 dB (A)
Indoor Unit: Sound Power Level (Hi/Mi/Lo) 43/39/36 dB 47/44/41 dB 51/48/45 dB 51/48/45 dB 54/52/49 dB 54/52/49 dB
Indoor Unit: Dimension H200 × W1,000 × D460 mm H245 × W1,000 × D700 mm H245 × W1,000 × D700 mm H245 × W1,000 × D700 mm H245 × W1,400 × D700 mm H245 × W1,400 × D700 mm
Indoor Unit: Package Dimension H275 × W1,300 × D580 mm H300 × W1,230 × D830 mm H300 × W1,230 × D830 mm H300 × W1,230 × D830 mm H300 × W1,630 × D830 mm H300 × W1,630 × D830 mm
Indoor Unit: Net Weight/Gross Weight 24.0/28.0 kg 32.0/37.0 kg 32.0/37.0 kg 32.0/37.0 kg 40.0/47.0 kg 40.0/47.0 kg
Outdoor Unit: Sound Pressure Level 53 dB (A) 54 dB (A) 56 dB (A) 56 dB (A) 57 dB (A) 58 dB (A)
Outdoor Unit: Sound Power Level 64 dB 65 dB 66 dB 66 dB 67 dB 68 dB
Outdoor Unit: Dimension H545 x W800 x D315 mm H655 x W825 x D310 mm H700 x W900 x D350 mm H805 x W970 x D395 mm H805 x W970 x D395 mm H1,325 x W940 x D370 mm
Outdoor Unit: Package Dimension H620 x W920 x D400 mm H725 x W945 x D435 mm H770 x W1,020 x D430 mm H890 x W1,105 x D495 mm H890 x W1,105 x D495 mm H1,440 x W1,080 x D430 mm
Outdoor Unit: Net Weight/Gross Weight 36.0/39.0 kg 44.0/47.5 kg 53.0/57.0 kg 62.0/66.0 kg 72.0/76.0 kg 93.0/103.0 kg
Outdoor Unit: Piping Connection (Gas Pipe) 12.7 mm (1/2 inch) 15.88 mm (5/8 inch) 15.88 mm (5/8 inch) 15.88 mm (5/8 inch) 15.88 mm (5/8 inch) 19.05 mm (3/4 inch)
Outdoor Unit: Piping Connection (Liquid Pipe) 6.35 mm (1/4 inch) 9.52 mm (3/8 inch) 9.52 mm (3/8 inch) 9.52 mm (3/8 inch) 9.52 mm (3/8 inch) 9.52 mm (3/8 inch)
Outdoor Unit: Pipe Length (Max) 30 m 30 m 30 m 50 m 50 m 50 m
Outdoor Unit: Elevation Difference 20 m 20 m 20 m 30 m 30 m 30 m
Outdoor Unit: Maximum Chargeless Length (Max) 5 m 5 m 5 m 5 m 5 m 5 m
Outdoor Unit: Additional Gas 30 g/m 50 g/m 50 g/m 50 g/m 50 g/m 50 g/m
Outdoor Unit: Operating Range, Outdoor (Min-Max) 17-49 °C 17-49 °C 17-49 °C 17-49 °C 17-49 °C 17-49 °C

Documents

Case Studies