Air-E (Ceiling Mounted nanoe™ X Generator) FV-15CSD1
NO ROOM TO ADD MORE PRODUCTS
The wishlist has already reached the maximum number of products
FV-15CSD1
nanoe™X – Panasonic’s revolutionary air purification technology
Features
Panasonic’s Air Conditioner with nanoe™ X Inhibited Over 99.7% of COVID-19 Virus (SARS-CoV-2) in 24 Hours
The objective of this test was to determine if nanoeTM X inhibits the activity of the SARS-CoV-2 virus. Gauze saturated with SARS-CoV-2 virus solution was exposed to an air conditioner with nanoeTM X from a distance of 0.7 m in a 6.7 m3 room. Virus activity inhibited by over 42.4% in 4 hours, and by over 91.4% in 8 hours and by over 99.7% in 24 hours.
(1) Testing organisation: Texcell (France) (2) Test subject: Adhered novel coronavirus (SARS-CoV-2) (3) Test volume: 6.7m3 room (1.7m × 1.8m × 2.2m) (4) Exposure distance: 0.7m
nanoe™ X inhibits activity of adhered novel coronavirus (SARS-CoV-2) over 99.99% in 2 hours
The objective of this test was to determine if nanoe™ X inhibit the activity of the SARS-CoV-2 virus. Gauze saturated with SARS-CoV-2 virus solution was exposed to a generator of nanoe™ X from a distance of 15cm in a 45L box for 2 hours. Over 99.99% of the activity of the SARS-CoV-2 virus was inhibited.
(1) Testing organisation: TEXCELL (France). (2) Test subject: novel coronavirus (SARS-CoV-2). (3) Test volume:
45L enclosed box (400 mm × 350 mm × 350 mm). (4) Exposure time: 2 hours. (5) Exposure distance: 15cm.
Press Release
Test Report
Panasonic’s Unique nanoe™X Technology
nanoe™ X lasts approximately 6 times longer than general ions and effectively reaches a wider area
7 Benefits of nanoe™ X
• Inhibiting activity of airborne*⁷ and adhered mould*⁸
• Inhibiting major allergens*⁹
• Inhibiting pollens*¹⁰
• Inhibition of hazardous substances*¹¹ known to be found in PM2.5
• Eliminating odours*¹²-¹⁹
• Moisturised skin*²⁰-²¹, straighter and sleeker hair*²²
Inhibition of Viruses and Bacteria
Deodorization
Hydrates Skin and Hair
Easy Installation
Improve Your Indoor Air Quality
The Air-E (nanoe™ Generator) can be installed anywhere in homes or public spaces to purify indoor air with Panasonic’s unique nanoe™ X technology. Contact us to find out more.
Specs
Maintenance Free – No Filter Required
Silent Operation
Easy Installation (Ceiling Mounted)
Air Volume
-
[CMH]
15
Consumption [W]
-
4
Noise [dB(A)]
-
23.50
Ambient Temperature [℃]
-
-10°C ~ 40°C
IP Rating
Weight [kg]
-
1.10
Footnotes:
-
*1 (Airborne bacteria (Staphylococcus aureus)) [Testing organisation] Kitasato Research Center for Environmental Science [Testing method] The number of bacteria is measured after direct exposure in an approximately 25m³ sized airtight test room [Inhibition method] nanoe™ released [Test substance] Airborne bacteria [Test result] Inhibited by at least 99.7% in 4 hours (24_0301_1)
*2 (Adhered bacteria (O157)) [Testing organisation] Japan Food Research Laboratories [Testing method] Measured the number of bacteria adhered to a cloth in an approximately 45L sized airtight test room [Inhibition method] nanoe™ released [Test substance] Adhered bacteria [Test result] Inhibited by at least 99.99% in 1 hour (208120880_001)
*3 (Adhered bacteria (MRSA)) [Testing organisation] Japan Food Research Laboratories [Testing method] Measured the number of bacteria adhered to a cloth in an approximately 45L sized airtight test room [Inhibition method] nanoe™ released [Test substance] Adhered bacteria [Test result] Inhibited by at least 99.99% in 1 hour (208120880_002)
*4 (Airborne virus (bacteriophageΦχ174)) [Testing organisation] Kitasato Research Center for Environmental Science [Testing method] The number of virus is measured after direct exposure in an approximately 25m³ sized airtight test room [Inhibition method] nanoe™ released [Test substance] Airborne virus [Test result] Inhibited by at least 99.7% in 6 hours (24_0300_1)
*5 (Adhered virus (Influenza virus H1N1 subtype)) [Testing organisation] Kitasato Research Center for Environmental Science [Testing method] Measured the number of virus adhered to a cloth in an approximately 1m³ sized airtight test room [Inhibition method] nanoe™ released [Test substance] Adhered virus [Test result] Inhibited by at least 99.9% in 2 hours (21_0084_1)
*6 (Adhered virus (Poliovirus type1(Lsc-2ab))) [Testing organisation] Kitasato Research Center for Environmental Science [Testing method] Measured the number of virus adhered to a cloth in an approximately 45L sized airtight test room [Inhibition method] nanoe™ released [Test substance] Adhered virus [Test result] Inhibited by at least 99.7% in 2 hours (22_0096)
*7 [Testing organisation] Japan Food Research Laboratories [Testing method] Measured the number of mould altered in an approximately 23m³ sized test room [Inhibition method] nanoe™ released [Test substance] Airborne mould [Test result] Inhibited by at least 99% in 1 hour (205061541-001)
*8 [Testing organisation] Japan Food Research Laboratories [Testing method] Measured mould adhered to a cloth [Inhibition method] nanoe™ released [Test substance] Adhered mould [Test result] Inhibited by at least 99.5% in 8 hours (11038081001-02)
*9 [Testing organisation] Panasonic Product Analysis Center [Testing method] Verified using the electrophoresis method in an approximately 23m³ sized test room [Inhibition method] nanoe™ released [Test substance] Allergens (Dermatophagoides pteronyssinus, Dermatophagoides farina, Cedar, Cypress, Orchard grass, Ragweed, Alnus japonica, Japanese white birch, Artemisia, Olive, Juniper, Casuarina, Miscanthus, Timothy grass, Humulus japonicus, Alternaria, Aspergillus, Candida, Malassezia, Cockroach, Moth, Dog (dander), Cat (dander)) [Test result] Inhibiting effect was confirmed in 24 hours (4AA33-160615-F01, 4AA33-170301-F15, 4AA33-151001-F01, 4AA33-151028-F01, 4AA-33-160601-F01, 4AA33-160601-F02, 4AA33-160701-F01, 1V332-180301-F01, 4AA33-160615-F02, 4AA33-160615-F03, 4AA33-160620-F01)
*10 (Cedar, Cypress, Orchard grass, Ragweed, Alnus japonica, Japanese white birch, Artemisia, Olive, Juniper, Casuarina, Miscanthus, Timothy grass, Humulus japonicus pollen)
[Testing organisation] Panasonic Product Analysis Center [Testing method] Verified using the electrophoresis method in an approximately 23m³ sized test room
[Inhibition method] nanoe™ released [Test substance] Cedar, Cypress, Orchard grass, Ragweed, Alnus japonica, Japanese white birch, Artemisia, Olive, Juniper, Casuarina, Miscanthus, Timothy grass, Humulus japonicus pollen [Test result] Inhibiting effect was confirmed in 24 hours (4AA33-151015-F01, 4AA33-151028-F01, 4AA33-160601-F01, 4AA33-160601-F02, 4AA33-160701-F01, 1V332-180301-F01)
*11 [Testing organisation] Panasonic Product Analysis Center [Testing method] Measured the amount of attached organic substances in an approximately 23m³ sized test room
[Inhibition method] nanoe™ released [Test result] (Aromatic carboxylic acid (benzoic acid)) Broken down at least 99% in approximately 8 hours (Y17NF096)
(Paraffin (hexadecane)) Broken down at least 99% in approximately 16 hours (Y17NF089)
Results may vary based on usage, and seasonal and environmental variables (temperature and humidity). nanoe™ X and nanoe™ inhibit activity or growth of viruses, but do not prevent infection.
*12 [Testing organisation] Panasonic Product Analysis Center [Testing method] Verified using the six-level odour intensity scale method in an approximately 23m³ sized test room [Deodorisation method] nanoe™ released [Test substance] Surface-attached cigarette smoke odour [Test result] Odour intensity reduced by 2.4 levels in 12mins (4AA33-160615-N04)
*13 [Testing organisation] Panasonic Product Analysis Center [Testing method] Verified using the six-level odour intensity scale method in an approximately 23m³ sized test room
[Deodorisation method] nanoe™ released [Test substance] Surface-attached pet odour [Test result] Odour intensity reduced by 1.5 levels in 1 hour (4AA33-160315-A34) -
*14 [Testing organisation] Panasonic Product Analysis Center [Testing method] Verified using the six-level odour intensity scale method in an approximately 23m³ sized test room
[Deodorisation method] nanoe™ released [Test substance] Surface-attached durian odour [Test result] Odour intensity reduced by 1 level in 0.5 hours (1V332-180402-K01)
*15 [Testing organisation] Panasonic Product Analysis Center [Testing method] Verified using the six-level odour intensity scale method in an approximately 23m³ sized test room
[Deodorisation method] nanoe™ released [Test substance] Surface-attached BBQ odour [Test result] Odour intensity reduced by 1.2 levels in 2 hours (4AA33-151221-N01)
*16 [Testing organisation] Panasonic Product Analysis Center [Testing method] Verified using the six-level odour intensity scale method in an approximately 23m³ sized test room [Deodorisation method] nanoe™ released [Test substance] Surface-attached sweat odour [Test result] Odour intensity reduced by 1.1 levels in 1 hour (Y16HM016)
*17 [Testing organisation] Panasonic Product Analysis Center [Testing method] Verified using the six-level odour intensity scale method in an approximately 23m³ sized test room [Deodorisation method] nanoe™ released [Test substance] Surface-attached damp odour [Test result] Odour intensity reduced by 1.7 levels in 0.5 hours (Y16RA002).
*18 [Testing organisation] Panasonic Product Analysis Center [Testing method] Verified using the six-level odour intensity scale method in an approximately 23m³ sized test room [Deodorisation method] nanoe™ released [Test substance] Surface-attached garbage odour [Test result](Methylmercaptan) Odour intensity reduced by 1.2 levels in 0.5 hours (1V332-18220-K11) (Trimethylamine) Odour intensity reduced by 1.4 levels in 0.5 hours (1V332-180220-K12)
*19 Testing organisation] Odour and Aroma Design Course, Depar™ent of Integrated Informatics, Faculty of Informatics, Daido University [Testing method] Verified using the six-level odour intensity scale method in an approximately 23m³ sized test room [Deodorisation method] nanoe™ released [Test substance] Simulated body odour of middle-aged and older people attached to pillow cover [Test result] Odour intensity reduced by 0.65 levels in 6 hours
Deodorisation effect varies according to the environment (temperature and humidity), operation time, odour, and fabric types. It does not eliminate toxic substances in cigarettes (carbon monoxide, etc.). Odours that are continuously generated (e.g., building material odours and pet odours) are not completely eliminated.
*20 [Testing organisation] Panasonic Product Analysis Center [Testing method] Rest period: 90 minutes, nanoe™ exposure time: 60 minutes, retention: 60 minutes. 8 women aged 30~49 with dry to normal skin. [Test result] Change in skin moisture content equivalent to a 20 percentage point increase from 30% --> 50% in environmental humidity (USG-KT-14K-012-™)
*21 [Testing organisation] FCG Research Institute, Inc. [Testing method and test result] Of 20 women 40 ± 2 years old, 10 women used a nanoe™ generating device at home for 28 days, while the other 10 women used a device with no nanoe™ generating device for 28 days at home. (19104)
*22 [Testing organisation] Panasonic Product Analysis Center [Testing method and test result] Approximately 46m³ sized test room, room temperature 25 degrees Celsius, humidity 40%. Bundles (6 bundles) of hair were suspended 2m from a nanoe™ generating device, with repeated operation of the nanoe™ generating device: 8 hours on and 16 hours off. (USD-KS-15S-009-™) [Method] nanoe™ released [Test substance] Hair Individual results may vary based on usage, and seasonal and environmental variables (temperature and humidity).
*23 (1) Testing organisation: TEXCELL (France). (2) Test subject: novel coronavirus (SARS-CoV-2). (3) Test volume: 45L enclosed box (400 mm × 350 mm × 350 mm). (4) Exposure time: 2 hours. (5) Exposure distance: 15cm.
Notes: (1) The virus infectious titer was measured and used to calculate the inhibition rate. (2) This verification was designed to generate basic research data on the effects of nanoe™ X on the novel coronavirus in laboratory conditions. It was not designed to evaluate product performance.
Reviews
USER REVIEWS
Be the first to write a review.