H1 Type High Fresh Air Ducted
High static and large airflow ducted with fresh air intake
H1 Type High Static Ducted units offer improved design flexibility in extended duct layouts thanks to their increased external static pressure. They also provide 100% fresh air intake for ventilation.
![](/content/dam/pim/my/en/VR/VRF-S-/VRF-S-MH1-SPP/ast-2190325.jpg.pub.crop.pc.thumb.640.1200.jpg)
Please Select Your User Type
![](/etc/designs/panasonic/productpage-2-clientlibs/scene7/images/icn-spinicon.png)
![](/etc/designs/panasonic/productpage-2-clientlibs/scene7/images/icn-pinchzoom.png)
H1 Type High Fresh Air Ducted
Features
Cooling/Heating kW (rated) |
14.0/13.2 |
22.4/21.2 |
28.0/26.5 |
Cooling/Heating Btu/h (rated) |
47,800/45,000 |
76,400/72.300 |
95,500/90,400 |
Model No. |
S-140MH1H5 |
S-224MH1H5 |
S-280MH1H5 |
![]() |
![]() |
![]() |
Fresh Air Intake Possible
High Fresh System enables the delivery of fresh outside air at almost the same temperature and humidity as indoor air without putting a burden on air conditioning.
Note: Capable of treating outdoor air only. Indoor air conditioner units are required to adjust indoor air temperature.
![Fresh Air Intake Possible](/content/dam/pim/my/en/VR/VRF-S-/VRF-S-MH1-SPP/ast-2190305.jpg.pub.thumb.644.644.jpg)
Mix Operation Unit with Standard Indoor Units
Possible to combine high fresh air ducted indoor units and standard air ducted indoor units. When other indoor units are connected in the same circuit, keep the following capacity ratio. H1 type / outdoor unit < 30%, and total of indoors (incl. H1) / outdoor < 100%
![Mix Operation Unit with Standard Indoor Units](/content/dam/pim/my/en/VR/VRF-S-/VRF-S-MH1-SPP/ast-2190306.jpg.pub.thumb.644.644.jpg)
3-Step Static Pressure Set Up
An inspection port (600 x 600 mm or more) is required at the lower side of the indoor unit body (field supply).
![3-Step Static Pressure Set Up](/content/dam/pim/my/en/VR/VRF-S-/VRF-S-MH1-SPP/ast-2234076.jpg.pub.thumb.644.644.jpg)
Leading Control Options
Panasonic air conditioning systems allow flexible control options. Individual, centralised, Cloud control and WLAN control are all possible. Please consult with a Panasonic air conditioning specialist for advice as to which control solution best suits your system requirements.
![Leading Control Options](/content/dam/pim/my/en/VR/VRF-S-/VRF-S-MT2-SPP/ast-2218338.jpg.pub.thumb.644.644.jpg)
Optional Parts for High Static Ducted Series
*Valve Kit is not required for cooling only system. For the details on the information, please consult an authorised dealer.
Specs
R410A
High Fresh Air
100% fresh air intake for ventilation purpose
Design flexibility with high static pressure and large air volume
Discharge air temperature control to reduce cold drafts during heating operation
Configurable air temperature control