Retail Sales Price: Panasonic Online Price: SHOP NOW SHOP NOW WHERE TO BUY Buy from Panasonic Where to Buy Out of Stock at Panasonic Online false false false

R32 Non-Inverter

SHOP NOW

R32 Non-Inverter

High energy-saving performance, compact, and easy to install

R32 Non-Inverter with environmentally friendly refrigerant delivers powerful performance with energy-efficiency. These compact outdoor units are designed to fit into any space or layout.
  • R32 Refrigerant
Zoom In
Zoom Out
Close

Features

Btu/h (rated)

19,500

26,000

31,000

31,000

36,000

42,000

48,500

52,500

Phase

1Ø Phase

1Ø Phase

1Ø Phase

3Ø Phase

3Ø Phase

3Ø Phase

3Ø Phase

3Ø Phase

Indoor Unit

S-19PU1H5C-1

S-25PU1H5C-1

S-30PU1H5C-1

S-30PU1H5C-1

S-36PU1H5C-1

S-42PU1H5C-1

S-50PU1H5C-1

S-55PU1H5C-1

Outdoor Unit

U-19PN1H5-1

U-25PN1H5-1

U-30PN1H5-1

U-30PN1H8-1

U-36PN1H8-1

U-42PN1H8-1

U-50PN1H8-1

U-55PN1H8-1

Eco-Friendly R32 Refrigerant

Panasonic recommends R32 because it is comparably environmentally friendly. Compared to R22 and R410A, R32 has a very low potential impact on the depletion of the ozone layer and global warming.
Eco-Friendly R32 Refrigerant

High Durable Outdoor Unit

Prevents Unit Stoppages Due to Short Circuits Caused by Geckos

One of the common causes of failures of the outdoor unit is geckos entering the unit. In this unit, the internal PCB has been removed to prevent electrical short circuits, thus eliminating any operation stoppages.
Note
・Supports for U-19PN1H5-1, U-25PN1H5-1, U-30PN1H5-1. Single phase only.
・The product image shown is for illustration purposes only and may not be an exact representation of the product.
Prevents Unit Stoppages Due to Short Circuits Caused by Geckos

In-House Manufactured Compressor with Outstanding Durability

Compressors are the heart of the air conditioner. Panasonic takes responsibility for the manufacture of all of its own products to ensure their durability.
Note: The product image shown is for illustration purposes only and may not be an exact representation of the product.
In-House Manufactured Compressor with Outstanding Durability

Rust-resistant and Easy to Maintain

Panasonic heat exchangers feature Blue Fin technology to prevent corrosion and ensure long-lasting performance. Panasonic uses a copper tube condenser, which makes it easy to repair and maintain.
Note
・Selecting this unit does not completely eliminate the possibility of rust developing. For details concerning unit installation and maintenance, please consult an authorised dealer.
・The product image shown is for illustration purposes only and may not be an exact representation of the product.
Rust-resistant and Easy to Maintain

Long Piping Allows Flexible Installation

The maximum chargeless piping length is 7.5 m, but it can be extended up to 50 m with additional gas charging for greater installation flexibility.
*Supports for U-42PN1H8-1, U-50PN1H8-1, U-55PN1H8-1 **Supports for U-30PN1H5-1, U-30PN1H8-1, U-36PN1H8-1, U-42PN1H8-1, U-50PN1H8-1, U-55PN1H8-1
Long Piping Allows Flexible Installation

Easy Installation

The maximum chargeless piping length is 7.5 m, but it can be extended up to 50 m with additional gas charging for greater installation flexibility.
*Supports for U-42PN1H8-1, U-50PN1H8-1, U-55PN1H8-1 **Supports for U-30PN1H5-1, U-30PN1H8-1, U-36PN1H8-1, U-42PN1H8-1, U-50PN1H8-1, U-55PN1H8-1
Long Piping Allows Flexible Installation

Panasonic outdoor units are designed to be compact enough to fit into any layout.
*Comparison between U-35PV1H8-1 and U-36PN1H8-1. **Comparison between U-55PV1H8-1 and U-55PN1H8-1. ***42PN: 75 kg, 50PN: 77 kg
A Compact Outdoor Unit for Places Where Space Is Limited

Specs

U-19PN1H5-1

Photo of U-19PN1H5-1

U-25PN1H5-1

Photo of U-25PN1H5-1

U-30PN1H5-1

Photo of U-30PN1H5-1

U-30PN1H8-1

Photo of U-30PN1H8-1

U-36PN1H8-1

Photo of U-36PN1H8-1

U-42PN1H8-1

Photo of U-42PN1H8-1

U-50PN1H8-1

Photo of U-50PN1H8-1

U-55PN1H8-1

Photo of U-55PN1H8-1
  • R32 RefrigerantR32 Refrigerant

Next generation R32 refrigerant

Space-saving outdoor unit

Flexible installation

High efficiency

Long piping

High durability outdoor unit

U-19PN1H5-1 U-25PN1H5-1 U-30PN1H5-1 U-30PN1H8-1 U-36PN1H8-1 U-42PN1H8-1 U-50PN1H8-1 U-55PN1H8-1
Sound Pressure Level 50 dB (A) 52 dB (A) 54 dB (A) 54 dB (A) 55 dB (A) 58 dB (A) 58 dB (A) 58 dB (A)
Sound Power Level 66 dB 68 dB 69 dB 69 dB 70 dB 72 dB 72 dB 72 dB
Dimension H619 x W824 x D299 mm H619 x W824 x D299 mm H695 x W875 x D320 mm H695 x W875 x D320 mm H695 x W875 x D320 mm H996 x W980 x D370 mm H996 x W980 x D370 mm H996 x W980 x D370 mm
Net Weight 36 kg 42 kg 56 kg 56 kg 56 kg 75 kg 78 kg 78 kg
Piping Connection (Gas Pipe) 12.70 mm (1/2 inch) 12.70 mm (1/2 inch) 15.88 mm (5/8 inch) 15.88 mm (5/8 inch) 15.88 mm (5/8 inch) 15.88 mm (5/8 inch) 15.88 mm (5/8 inch) 15.88 mm (5/8 inch)
Piping Connection (Liquid Pipe) 6.35 mm (1/4 inch) 6.35 mm (1/4 inch) 9.52 mm (3/8 inch) 9.52 mm (3/8 inch) 9.52 mm (3/8 inch) 9.52 mm (3/8 inch) 9.52 mm (3/8 inch) 9.52 mm (3/8 inch)
Pipe Length (Min-Max) 7.5-30 m 7.5-30 m 7.5-45 m 7.5-45 m 7.5-45 m 7.5-50 m 7.5-50 m 7.5-50 m
Elevation Difference 20 m 20 m 30 m 30 m 30 m 30 m 30 m 30 m
Maximum Chargeless Length (Max) 7.5 m 7.5 m 7.5 m 7.5 m 7.5 m 7.5 m 7.5 m 7.5 m
Refrigerant Type, Additional Gas R32, 15 g/m R32, 15 g/m R32, 25 g/m R32, 25 g/m R32, 25 g/m R32, 25 g/m R32, 25 g/m R32, 25 g/m
Operation Range, Outdoor (Min-Max) 16-43 °C 16-43 °C 16-43 °C 16-43 °C 16-43 °C 16-43 °C 16-43 °C 16-43 °C