Retail Sales Price: Panasonic Online Price: SHOP NOW SHOP NOW WHERE TO BUY Buy from Panasonic Where to Buy Out of Stock at Panasonic Online false false false

R410A Non-Inverter Fresh Series Ceiling Ducted

SHOP NOW

R410A Non-Inverter Fresh Series Ceiling Ducted

A slim-type model with a rear air intake that remains concealed in the ceiling

R410A Non-Inverter Fresh Series Ceiling Ducted units are suitable for premises with concealed or false ceilings, such as business centers. The rear air intake is standard.
  • Fresh Series
  • R410A
Zoom In
Zoom Out
Close
R410A Non-Inverter Fresh Series Ceiling Ducted

Features

Btu/h (rated)

18,000

24,000

30,000

36,000

48,000

60,000

Phase

1Ø Phase

1Ø Phase

1Ø Phase

3Ø Phase

3Ø Phase

3Ø Phase

Indoor Unit

S-18PFB1H5

S-24PFB1H5

S-30PFB1H5

S-36PFB1H5

S-48PFB1H5

S-60PFB1H5

Outdoor Unit

U-18PVB1H5

U-24PVB1H5

U-30PVB1H5

U-36PVB1H8

U-48PVB1H8

U-60PVB1H8

Enables Air Conditioning Without Disturbing Quiet Spaces

Features a low sound pressure level of 25 dB(A), as quiet as that of rustling leaves. It is ideal for quiet and relaxing spaces, such as hotel lobbies and guest rooms, thanks to its superior quiet performance.
Enables Air Conditioning Without Disturbing Quiet Spaces

Precise Control, Easy Comfort

Panasonic Fresh Series remote controllers are designed with user convenience in mind. Multiple settings are available so airflow and air quality can be regulated according to preferences.
Precise Control, Easy Comfort

Compact Outdoor Unit

Compact outdoor units are built to be compact with versatile piping and draining methods and offer side-by-side installation capability.
Compact Outdoor Unit

Easily Installed in Limited Spaces

The unit has a height of only 290 mm, so it allows installation in limited ceiling spaces. The lightweight, attractive design simplifies installation and matches virtually all room interiors.
Easily Installed in Limited Spaces

Specs

S-18PFB1H5_U-18PVB1H5

Photo of S-18PFB1H5_U-18PVB1H5

S-24PFB1H5_U-24PVB1H5

Photo of S-24PFB1H5_U-24PVB1H5

S-30PFB1H5_U-30PVB1H5

Photo of S-30PFB1H5_U-30PVB1H5

S-36PFB1H5_U-36PVB1H8

Photo of S-36PFB1H5_U-36PVB1H8

S-48PFB1H5_U-48PVB1H8

Photo of S-48PFB1H5_U-48PVB1H8

S-60PFB1H5_U-60PVB1H8

Photo of S-60PFB1H5_U-60PVB1H8
  • Fresh SeriesFresh Series
  • R410AR410A

Interchangeable air intake

The slim design makes height only 290 mm

Precise control, easy comfort

Wired remote controller included

S-18PFB1H5_U-18PVB1H5 S-24PFB1H5_U-24PVB1H5 S-30PFB1H5_U-30PVB1H5 S-36PFB1H5_U-36PVB1H8 S-48PFB1H5_U-48PVB1H8 S-60PFB1H5_U-60PVB1H8
Power Source 220-240 V, 1 phase - 50 Hz 220-240 V, 1 phase - 50 Hz 220-240 V, 1 phase - 50 Hz 380-415 V, 3 phase - 50 Hz 380-415 V, 3 phase - 50 Hz 380-415 V, 3 phase - 50 Hz
Indoor S-18PFB1H5 S-24PFB1H5 S-30PFB1H5 S-36PFB1H5 S-48PFB1H5 S-60PFB1H5
Outdoor U-18PVB1H5 U-24PVB1H5 U-30PVB1H5 U-36PVB1H8 U-48PVB1H8 U-60PVB1H8
Cooling Capacity: Rated 5.30 kW, 18,000 Btu/h 7.20 kW, 24,000 Btu/h 8.21 kW, 30,000 Btu/h 10.60 kW, 36,000 Btu/h 14.00 kW, 48,000 Btu/h 17.60 kW, 60,000 Btu/h
Current 8.00 A 9.50 A 11.00 A 6.69 A 10.00 A 12.00 A
Power Input: Rated 1.73 kW 2.39 kW 2.42 kW 3.73 kW 4.87 kW 5.71 kW
COP/EER 3.06 W/W, 10.44 Btu/hW 3.01 W/W, 10.27 Btu/hW 3.39 W/W, 11.57 Btu/hW 2.84 W/W, 9.69 Btu/hW 2.87 W/W, 9.79 Btu/hW 3.08 W/W, 10.51 Btu/hW
External Static Pressure 50 Pa 50 Pa 50 Pa 50 Pa 80 Pa 80 Pa
Indoor Unit: Air Volume (Hi/Mi/Lo) 15.8/13.3/11.7 m³/min, 564/475/418 cfm 21.7/20.8/19.2 m³/min, 775/743/685 cfm 27.5/24.2/20.8 m³/min, 982/864/743 cfm 27.5/24.2/20.8 m³/min, 982/864/743 cfm 35/33.3/26.7 m³/min, 1,250/1,189/953 cfm 35/33.3/26.7 m³/min, 1,250/1,189/953 cfm
Indoor Unit: Sound Pressure Level (Hi/Mi/Lo) 44/41/35 dB (A) 47/44/38 dB (A) 50/47/41 dB (A) 50/47/41 dB (A) 51/49/46 dB (A) 53/50/44 dB (A)
Indoor Unit: Sound Power Level (Hi/Mi/Lo) 52/49/43 dB 55/52/46 dB 59/56/50 dB 59/56/50 dB 61/59/56 dB 63/60/54 dB
Indoor Unit: Dimension H290 × W890 × D735 mm H290 × W890 × D735 mm H290 × W890 × D735 mm H290 × W890 × D735 mm H290 × W1,250 × D735 mm H290 × W1,250 × D735 mm
Indoor Unit: Package Dimension H360 × W1,070 × D800 mm H360 × W1,070 × D800 mm H360 × W1,070 × D800 mm H360 × W1,070 × D800 mm H360 × W1,430 × D800 mm H360 × W1,430 × D800 mm
Indoor Unit: Net Weight/Gross Weight 34.0/40.0 kg 36.0/42.0 kg 36.0/42.0 kg 36.0/42.0 kg 45.0/51.0 kg 45.0/51.0 kg
Outdoor Unit: Sound Pressure Level 55 dB (A) 60 dB (A) 58 dB (A) 60 dB (A) 60 dB (A) 60 dB (A)
Outdoor Unit: Sound Power Level 63 dB 68 dB 67 dB 69 dB 70 dB 70 dB
Outdoor Unit: Dimension H545 x W800 x D315 mm H655 x W825 x D310 mm H700 x W900 x D350 mm H805 x W970 x D395 mm H1,325 x W940 x D340 mm H1,325 x W940 x D340 mm
Outdoor Unit: Package Dimension H620 x W920 x D400 mm H725 x W945 x D435 mm H770 x W1,020 x D430 mm H890 x W1,105 x D495 mm H1,435 x W1,070 x D450 mm H1,435 x W1,070 x D450 mm
Outdoor Unit: Net Weight/Gross Weight 36.0/39.0 kg 45.0/48.5 kg 55.0/59.0 kg 68.0/72.5 kg 95.0/105.0 kg 104.5/109.5 kg
Outdoor Unit: Piping Connection (Gas Pipe) 12.7 mm (1/2 inch) 15.88 mm (5/8 inch) 15.88 mm (5/8 inch) 15.88 mm (5/8 inch) 19.05 mm (3/4 inch) 19.05 mm (3/4 inch)
Outdoor Unit: Piping Connection (Liquid Pipe) 6.35 mm (1/4 inch) 9.52 mm (3/8 inch) 9.52 mm (3/8 inch) 9.52 mm (3/8 inch) 9.52 mm (3/8 inch) 9.52 mm (3/8 inch)
Outdoor Unit: Pipe Length (Max) 30 m 30 m 30 m 50 m 50 m 50 m
Outdoor Unit: Elevation Difference 15 m 20 m 20 m 30 m 30 m 30 m
Outdoor Unit: Maximum Chargeless Length (Max) 5 m 5 m 5 m 5 m 5 m 5 m
Outdoor Unit: Additional Gas 20 g/m 40 g/m 40 g/m 40 g/m 40 g/m 40 g/m
Outdoor Unit: Operating Range, Outdoor (Min-Max) 17-49 °C 17-49 °C 17-49 °C 17-49 °C 17-49 °C 17-49 °C

Documents

Case Studies