Retail Sales Price: Panasonic Online Price: SHOP NOW SHOP NOW WHERE TO BUY Buy from Panasonic Where to Buy Out of Stock at Panasonic Online false false false

R32 Non-Inverter Fresh Series Ceiling and Console

SHOP NOW

R32 Non-Inverter Fresh Series Ceiling and Console

Slim design that can be installed vertically or horizontally and delivers airflow far and wide

R32 Non-Inverter Fresh Series Ceiling and Console units provide comfort as well as far, wide airflow distribution. At just 235 mm thick and able to be installed vertically or horizontally, the slim design of these units is perfect for retail stores and schools.
  • Fresh Series
  • R32
Zoom In
Zoom Out
Close
R32 Non-Inverter Fresh Series Ceiling and Console

Features

Btu/h (rated)

18,000

24,000

30,000

36,000

48,000

60,000

Phase

1Ø Phase

1Ø Phase

1Ø Phase

3Ø Phase

3Ø Phase

3Ø Phase

Indoor Unit

S-18PTB1H5B

S-24PTB1H5B

S-30PTB1H5B

S-36PTB1H5B

S-48PTB1H5B

S-60PTB1H5B

Outdoor Unit

U-18PNB1H5

U-24PNB1H5

U-30PNB1H5

U-36PNB1H8

U-48PNB1H8

U-60PNB1H8

Slim Design

The slim design makes thickness only 235 mm.
Slim Design

Precise Control, Easy Comfort

Panasonic Fresh Series remote controllers are designed with user convenience in mind. Multiple settings are available so airflow and air quality can be regulated according to preferences. Users may choose a wireless remote controller CZ-RWCB1H* or a wired remote controller CZ-RTCB1H (optional) equipped with a high-performance timer.
*A wireless remote controller is in the same package with the indoor unit.
Precise Control, Easy Comfort

Compact Outdoor Unit

Compact outdoor units are built to be compact with versatile piping and draining methods and offer side-by-side installation capability.
Compact Outdoor Unit

Specs

S-18PTB1H5B_U-18PNB1H5

Photo of S-18PTB1H5B_U-18PNB1H5

S-24PTB1H5B_U-24PNB1H5

Photo of S-24PTB1H5B_U-24PNB1H5

S-30PTB1H5B_U-30PNB1H5

Photo of S-30PTB1H5B_U-30PNB1H5

S-36PTB1H5B_U-36PNB1H8

Photo of S-36PTB1H5B_U-36PNB1H8

S-48PTB1H5B_U-48PNB1H8

Photo of S-48PTB1H5B_U-48PNB1H8

S-60PTB1H5B_U-60PNB1H8

Photo of S-60PTB1H5B_U-60PNB1H8
  • Fresh SeriesFresh Series
  • R32R32

The slim design makes thickness only 235 mm

Vertical installation (as floor standing)

Precise control, easy comfort

Wireless remote controller included

S-18PTB1H5B_U-18PNB1H5 S-24PTB1H5B_U-24PNB1H5 S-30PTB1H5B_U-30PNB1H5 S-36PTB1H5B_U-36PNB1H8 S-48PTB1H5B_U-48PNB1H8 S-60PTB1H5B_U-60PNB1H8
Power Source 220-240 V, 1 phase - 50 Hz 220-240 V, 1 phase - 50 Hz 220-240 V, 1 phase - 50 Hz 380-415 V, 3 phase - 50 Hz 380-415 V, 3 phase - 50 Hz 380-415 V, 3 phase - 50 Hz
Indoor S-18PTB1H5B S-24PTB1H5B S-30PTB1H5B S-36PTB1H5B S-48PTB1H5B S-60PTB1H5B
Outdoor U-18PNB1H5 U-24PNB1H5 U-30PNB1H5 U-36PNB1H8 U-48PNB1H8 U-60PNB1H8
Cooling Capacity: Rated 5.28 kW, 18,000 Btu/h 7.03 kW, 24,000 Btu/h 8.79 kW, 30,000 Btu/h 10.55 kW, 36,000 Btu/h 14.07 kW, 48,000 Btu/h 17.58 kW, 60,000 Btu/h
Current 8.00 A 10.40 A 12.50 A 6.69 A 8.35 A 10.00 A
Power Input: Rated 1.76 kW 2.34 kW 2.74 kW 3.6 kW 4.67 kW 5.71 kW
COP/EER 3.00 W/W, 10.24 Btu/hW 3.00 W/W, 10.25 Btu/hW 3.21 W/W, 10.95 Btu/hW 2.93 W/W, 10.00 Btu/hW 3.01 W/W, 10.28 Btu/hW 3.08 W/W, 10.50 Btu/hW
Indoor Unit: Air Volume (Hi/Mi/Lo) 15.8/11.6/9.3 m³/min, 558/410/328 cfm 18.3/13.3/11 m³/min, 646/470/388 cfm 25.3/21/13.3 m³/min, 893/742/470 cfm 25.3/21/13.3 m³/min, 893/742/470 cfm 35.8/31.6/22.5 m³/min, 1,264/1,116/795 cfm 35.8/31.6/22.5 m³/min, 1,264/1,116/795 cfm
Indoor Unit: Sound Pressure Level (Hi/Mi/Lo) 44/38/33 dB (A) 46/40/35 dB (A) 50/46/42 dB (A) 50/46/42 dB (A) 52/47/43 dB (A) 52/47/43 dB (A)
Indoor Unit: Sound Power Level (Hi/Mi/Lo) 52/46/41 dB 56/50/45 dB 59/55/51 dB 59/55/51 dB 62/57/53 dB 62/57/53 dB
Indoor Unit: Dimension H235 × W1,000 × D690 mm H235 × W1,000 × D690 mm H235 × W1,280 × D690 mm H235 × W1,280 × D690 mm H235 × W1,600 × D690 mm H235 × W1,600 × D690 mm
Indoor Unit: Package Dimension H325 × W1,080 × D770 mm H325 × W1,080 × D770 mm H325 × W1,360 × D770 mm H325 × W1,360 × D770 mm H325 × W1,680 × D770 mm H325 × W1,680 × D770 mm
Indoor Unit: Net Weight/Gross Weight 28.0/32.0 kg 29.0/33.0 kg 36.0/42.0 kg 36.0/42.0 kg 41.0/48.0 kg 41.0/48.0 kg
Outdoor Unit: Sound Pressure Level 53 dB (A) 54 dB (A) 56 dB (A) 56 dB (A) 57 dB (A) 58 dB (A)
Outdoor Unit: Sound Power Level 64 dB 65 dB 66 dB 66 dB 67 dB 68 dB
Outdoor Unit: Dimension H545 x W800 x D315 mm H655 x W825 x D310 mm H700 x W900 x D350 mm H805 x W970 x D395 mm H805 x W970 x D395 mm H1,325 x W940 x D370 mm
Outdoor Unit: Package Dimension H620 x W920 x D400 mm H725 x W945 x D435 mm H770 x W1,020 x D430 mm H890 x W1,105 x D495 mm H890 x W1,105 x D495 mm H1,440 x W1,080 x D430 mm
Outdoor Unit: Net Weight/Gross Weight 36.0/39.0 kg 44.0/47.5 kg 53.0/57.0 kg 62.0/66.0 kg 72.0/76.0 kg 93.0/103.0 kg
Outdoor Unit: Piping Connection (Gas Pipe) 12.70 mm (1/2 inch) 15.88 mm (5/8 inch) 15.88 mm (5/8 inch) 15.88 mm (5/8 inch) 15.88 mm (5/8 inch) 19.05 mm (3/4 inch)
Outdoor Unit: Piping Connection (Liquid Pipe) 6.35 mm (1/4 inch) 9.52 mm (3/8 inch) 9.52 mm (3/8 inch) 9.52 mm (3/8 inch) 9.52 mm (3/8 inch) 9.52 mm (3/8 inch)
Outdoor Unit: Pipe Length (Max) 30 m 30 m 30 m 50 m 50 m 50 m
Outdoor Unit: Elevation Difference 20 m 20 m 20 m 30 m 30 m 30 m
Outdoor Unit: Maximum Chargeless Length (Max) 5 m 5 m 5 m 5 m 5 m 5 m
Outdoor Unit: Additional Gas 30 g/m 50 g/m 50 g/m 50 g/m 50 g/m 50 g/m
Outdoor Unit: Operating Range, Outdoor (Min-Max) 17-49 °C 17-49 °C 17-49 °C 17-49 °C 17-49 °C 17-49 °C

Documents

Case Studies