Retail Sales Price: Panasonic Online Price: SHOP NOW SHOP NOW WHERE TO BUY Buy from Panasonic Where to Buy Out of Stock at Panasonic Online false false /vn/en/air-solutions/contact-for-home.html false

R32/R410A Inverter Floor Standing with nanoe™ X

CONTACT US

R32/R410A Inverter Floor Standing with nanoe™ X

Superior air purification performance with adjustable airflow direction

R32/R410A Inverter Floor Standing with nanoe™ X units offer more efficient air protection with nanoe X Generator Mark2 and adjustable airflow direction for a comfortable space for all. These units are also easy to install and easy to clean.
  • nanoe X Generator Mark2
  • Inverter
  • R32 Refrigerant (S-21/24PB3H5)
  • R410A (S-34/43/48PB3H5)
Zoom In
Zoom Out
Close
R32/R410A Inverter Floor Standing with nanoe™ X

Features

Btu/h (rated)

20,500

24,600

34,100

42,700

47,750

Phase

1Ø Phase

1Ø Phase

1Ø Phase

1Ø Phase

1Ø Phase

Refrigerant

R32

R410A

Indoor Unit

S-21PB3H5

S-24PB3H5

-

-

-

Indoor Unit

-

-

S-34PB3H5

S-43PB3H5

S-48PB3H5

Outdoor Unit

U-21PRB1H5

U-24PRB1H5

U-34PSB3H5

U-43PSB3H5

U-48PSB3H5

More Efficient Air Protection with nanoe X Generator Mark2

24-hour nanoe™ X Air Protection

nanoe™ X inhibits certain bacteria, viruses, pollens, allergens, and mould, and hazardous substances contained in PM2.5. Providing effective deodorisation and improving the quality of your air. nanoe™ X functions in the cooling mode and is maintenance-free, helping you enjoy 24 hours of quality air while keeping your costs down.
24-hour nanoe™ X Air Protection

Effective at Eliminating Odours in Half the Time

The nanoe X Generator Mark2 reduces odours by as much as 1.8 levels* in just half the time of the conventional nanoe X Generator Mark1.
*A 1.8 level decrease in odour intensity is equivalent to a reduction of 95% or more.
[Odour intensity] 5: Very strong odour, 4: Strong odour, 3: Easily detectable odour, 2: Weak, recognisable odour (cognitive threshold concentration), 1: Barely detectable odour (detection threshold concentration), 0: No odour

Note: The test result is obtained using a 4-Way Cassette. **Testing Overview: [Testing organisation] Panasonic Product Analysis Center [Test method] Verification in a test room (approx. 230 m³ (6.8 x 8.5 x 4.0 m)) using a 6-step odour intensity display method [Method of deodorisation] Operation of a CS-P80U6 equipped with a nanoe X Generator Mark1 and release of nanoe™ [Target] Adhered aging odour (nonenal) [Test Result] Odour intensity reduced by 1.8 in 120 minutes (L19YK032-01) ***Testing Overview: [Testing organisation] Panasonic Product Analysis Center [Test method] Verification in a test room (approx. 230 m³ (6.8 x 8.5 x 4.0 m)) using a 6-step odour intensity display method [Method of deodorisation] Operation of a CS-P80U6 equipped with a nanoe X Generator Mark2 and release of nanoe™ [Target] Adhered aging odour (nonenal) [Test Result] Odour intensity reduced by 1.8 in 60 minutes (L19YK032-01)
Effective at Eliminating Odours in Half the Time

Airflow Creates a Comfortable and Cool Environment

Cools the Area Quickly

Powerful airflow instantly makes spaces comfortable and cool.
Note: This table shows values for the airflow rate in high mode.
Cools the Area Quickly

Delivers Cool Air Over a Long Distance

Cool air can reach up to a distance of 11 meters, so even deep and wide spaces are comfortable.
Note: Up to 11 m (S-34PB3H5, S-43PB3H5, S-48PB3H5), Up to 7 m (S-21PB3H5, S-24PB3H5)
Delivers Cool Air Over a Long Distance

Cools Spaces in Their Entirety

The direction of the louvers can be adjusted up and down, and left and right at the touch of a button.* You can choose to distribute cool air to every part of a large space or deliver cool air to only places where you want it to go. You can use the unit in any way you like.
*Up/Down: Manual setting for S-34PB3H5, S-43PB3H5, S-48PB3H5. Right/Left: Setting via remote controller for all models.
Cools Spaces in Their Entirety

Auto Fan Mode Adjusts to Suit Your Environment

When the auto fan mode is set, the indoor unit of the air conditioner automatically is adjusted the suitable fan speed according to factors such as load.
Auto Fan Mode Adjusts to Suit Your Environment

Excellent Design and Operability

Stylish Design with New Control Panel

The stylish design and easy-to-use control panel makes it easy to see when the nanoe™ X is running.
Stylish Design with New Control Panel

Random Auto Restart for After Power Outage

When there is a power outage, it automatically restarts the operating that was in progress before power was lost.
Random Auto Restart for After Power Outage

Flexible and Efficient Timer Settings to Meet Your Needs

You can set the start and stop time to within 12 hours from the current time, and use the system flexibly according to your business needs, such as automatic on to maintain a cool and comfortable office environment, or automatic off to prevent forgetting to turn the system off.
Flexible and Efficient Timer Settings to Meet Your Needs

Specs

S-21PB3H5_U-21PRB1H5

Photo of S-21PB3H5_U-21PRB1H5

S-24PB3H5_U-24PRB1H5

Photo of S-24PB3H5_U-24PRB1H5

S-34PB3H5_U-34PSB3H5

Photo of S-34PB3H5_U-34PSB3H5

S-43PB3H5_U-43PSB3H5

Photo of S-43PB3H5_U-43PSB3H5

S-48PB3H5_U-48PSB3H5

Photo of S-48PB3H5_U-48PSB3H5
  • nanoe X Generator Mark2nanoe X Generator Mark2
  • InverterInverter
  • R32 Refrigerant (S-21/24PB3H5)R32 Refrigerant (S-21/24PB3H5)
  • R410A (S-34/43/48PB3H5)R410A (S-34/43/48PB3H5)

The first floor-standing unit with nanoe™ X as standard

More sophisticated design, including new control panel

More compact unit 34,100 btu new model odu for easy transport & installation

Vertical and horizontal airflow

12-hour on/off delay setting timer

Wireless remote controller included

S-21PB3H5_U-21PRB1H5 S-24PB3H5_U-24PRB1H5 S-34PB3H5_U-34PSB3H5 S-43PB3H5_U-43PSB3H5 S-48PB3H5_U-48PSB3H5
Power Source 220/230 V, 1 phase - 50 Hz 220/230 V, 1 phase - 50 Hz 220/230 V, 1 phase - 50 Hz 220/230 V, 1 phase - 50 Hz 220/230 V, 1 phase - 50 Hz
Indoor S-21PB3H5 S-24PB3H5 S-34PB3H5 S-43PB3H5 S-48PB3H5
Outdoor U-21PRB1H5 U-24PRB1H5 U-34PSB3H5 U-43PSB3H5 U-48PSB3H5
Cooling Capacity: Rated 6.05 kW, 20,500 Btu/h 7.25 kW, 24,600 Btu/h 10.00 kW, 34,100 Btu/h 12.53 kW, 42,700 Btu/h 14.00 kW, 47,750 Btu/h
Cooling Capacity: Min-Max 1.00-6.60 kW, 3,410-22,500 Btu/h 1.00-7.50 kW, 3,410-25,570 Btu/h 1.20-10.30 kW, 4,090-35,120 Btu/h 2.00-13.50 kW, 6,820-46,030 Btu/h 2.00-14.60 kW, 6,820-49,780 Btu/h
Current: Rated (Max) 8.00 A (11.2 A) 11.2 A (13.7 A) 15.1 A (16.9 A) 20.3 A (26.9 A) 25.6 A (28.1 A)
Cooling Power Input: Rated (Min-Max) 1.80 kW (0.21-2.30 kW) 2.55 kW (0.21-2.80 kW) 3.45 kW (0.30-3.60 kW) 4.47 kW (0.80-5.00 kW) 5.60 kW (0.80-5.70 kW)
Cooling Rated COP/EER 3.36 W/W, 11.3 Btu/hW 2.84 W/W, 9.64 Btu/hW 2.89 W/W, 9.88 Btu/hW 2.80 W/W, 9.55 Btu/hW 2.50 W/W, 8.52 Btu/hW
Indoor Unit: Cooling Air Volume 15.5 m³/min, 547 cfm 15.5 m³/min, 547 cfm 32.0 m³/min, 1,130 cfm 32.0 m³/min, 1,130 cfm 32.0 m³/min, 1,130 cfm
Indoor Unit: Sound Pressure Level (Hi/Lo) 45/31 dB (A) 45/33 dB (A) 53/44 dB (A) 53/44 dB (A) 53/44 dB (A)
Indoor Unit: Sound Power Level (Hi/Lo) 58/44 dB 58/46 dB 66/57 dB 66/57 dB 66/57 dB
Indoor Unit: Dimension H1,680 × W500 × D318 mm H1,680 × W500 × D318 mm H1,880 × W600 × D357 mm H1,880 × W600 × D357 mm H1,880 × W600 × D357 mm
Indoor Unit: Net Weight 29 kg 29.5 kg 45.0 kg 45.0 kg 45.0 kg
Outdoor Unit: Sound Pressure Level 53 dB (A) 54 dB (A) 54 dB (A) 55 dB (A) 56 dB (A)
Outdoor Unit: Sound Power Level 66 dB 67 dB 67 dB 68 dB 69 dB
Outdoor Unit: Dimension H626 x W825 x D320 mm H626 x W825 x D320 mm H786 x W900 x D320 mm H996 x W940 x D340 mm H996 x W940 x D340 mm
Outdoor Unit: Net Weight 35.0 kg 36.0 kg 45.0 kg 74.0 kg 74.0 kg
Outdoor Unit: Piping Connection (Gas Pipe) 12.70 mm (4/8 inch) 15.88 mm (5/8 inch) 15.88 mm (5/8 inch) 15.88 mm (5/8 inch) 15.88 mm (5/8 inch)
Outdoor Unit: Piping Connection (Liquid Pipe) 6.35 mm (1/4 inch) 6.35 mm (1/4 inch) 6.35 mm (1/4 inch) 9.52 mm (3/8 inch) 9.52 mm (3/8 inch)
Outdoor Unit: Pipe Length (Min-Max) 3-40 m 3-40 m 7.5-50 m 7.5-50 m 7.5-50 m
Outdoor Unit: Elevation Difference (Upper) 20 m 20 m 20 m 30 m 30 m
Outdoor Unit: Maximum Chargeless Length (Max) 15 m 15 m 20 m 20 m 20 m
Outdoor Unit: Additional Gas 10 g/m 10 g/m 40 g/m 50 g/m 50 g/m
Outdoor Unit: Operating Range, Outdoor (Min-Max) 18-43 °C 18-43 °C 18-43 °C 18-43 °C 18-43 °C

Documents

Case Studies