Retail Sales Price: Panasonic Online Price: SHOP NOW SHOP NOW WHERE TO BUY Buy from Panasonic Where to Buy Out of Stock at Panasonic Online false false false

R32 Heat Pump Inverter 4-Way Cassette

SHOP NOW

R32 Heat Pump Inverter 4-Way Cassette

Delivers superior air purification and convenience with a new IoT remote controller

R32 Heat Pump Inverter 4-Way Cassettes, with 360° comfortable airflow, offer more efficient air protection with nanoe X Generator Mark2. A new IoT remote controller also provides great accessibility and convenience.
  • nanoe X Generator Mark2
  • Comfort Cloud App
  • CONEX
  • Inverter
Zoom In
Zoom Out
Close
R32 Heat Pump Inverter 4-Way Cassette

Features

Btu/h (rated)

17,100

20,500

24,200

34,100

42,700

47,800

42,700

47,800

Phase

1Φ Phase

1Φ Phase

1Φ Phase

3Ø Phase

Indoor Unit

S-18PU3HB

S-2124PU3HB

S-3448PU3HB

S-3448PU3HB

Outdoor Unit

U-18PZ3H5

U-21PZ3H5

U-24PZ3H5

U-34PZ3H5

U-43PZ3H5

U-48PZ3H5

U-43PZ3H8

U-48PZ3H8

More Efficient Air Protection with nanoe X Generator Mark2

24-hour nanoe™ X Air Protection

Maintain quality air 24-hours a day by turning on nanoe™ X using the Panasonic Comfort Cloud app. nanoe™ X inhibits certain bacteria, viruses, pollens, allergens, mould, and hazardous substances found in PM2.5, providing effective deodorization and improving the air quality.
24-hour nanoe™ X Air Protection

Effective at Eliminating Odours in Half the Time

The nanoe X Generator Mark2 reduces odours by as much as 1.8 levels* in just half the time of the conventional nanoe X Generator Mark1.
*A 1.8 level decrease in odour intensity is equivalent to a reduction of 95% or more.
[Odour intensity] 5: Very strong odour, 4: Strong odour, 3: Easily detectable odour, 2: Weak, recognisable odour (cognitive threshold concentration), 1: Barely detectable odour (detection threshold concentration), 0: No odour

**Testing Overview: [Testing organisation] Panasonic Product Analysis Center [Test method] Verification in a test room (approx. 230 m³ (6.8 x 8.5 x 4.0 m)) using a 6-step odour intensity display method [Method of deodorisation] Operation of a CS-P80U6 equipped with a nanoe X Generator Mark1 and release of nanoe™ [Target] Adhered aging odour (nonenal) [Test Result] Odour intensity reduced by 1.8 in 120 minutes (L19YK032-01) ***Testing Overview: [Testing organisation] Panasonic Product Analysis Center [Test method] Verification in a test room (approx. 230 m³ (6.8 x 8.5 x 4.0 m)) using a 6-step odour intensity display method [Method of deodorisation] Operation of a CS-P80U6 equipped with a nanoe X Generator Mark2 and release of nanoe™ [Target] Adhered aging odour (nonenal) [Test Result] Odour intensity reduced by 1.8 in 60 minutes (L19YK032-01)
Effective at Eliminating Odours in Half the Time

Inside Cleaning Function Prevents Mould and Eliminates Odours

nanoe™ X also keeps the inside of the air conditioner clean. After the cooling/drying operation, the interior of the indoor unit dries itself automatically.* nanoe™ X is activated to suppress mould growth and to reduce odours.
*If you wish to set the inside cleaning function off, use the wireless RC to turn the function off. Please consult an authorized dealer for setting.
Note: The product image shown is for illustration purposes only and may not be an exact representation of the product.
Inside Cleaning Function Prevents Mould and Eliminates Odours

Smart Power Saving with IoT

A Next-Generation Remote Control Solution Optimised for Usability, Whatever Your Needs

CONEX goes beyond simple remote control to combine sophistication with simplicity, offering IoT integration that connects directly to a variety of apps for next-generation solutions.
Note: A wireless remote controller is provided with the product.
A Next-Generation Remote Control Solution Optimised for Usability, Whatever Your Needs

Smart Management of Power Consumption

Using the Panasonic Comfort Cloud app enables the air conditioner to be controlled from anywhere with a mobile device. Thus, there is no need to worry if someone forgets to turn off the office air conditioner. The power consumption can also be monitored to help reduce electricity waste.
Note: CZ-CAPWFC1 External WLAN Adaptor or CZ-RTC6BLW are required per unit.
Smart Management of Power Consumption

Industry-Leading Airflow for Cooling Comfort

Cools the Area Quickly

The Turbo Fan with Twisted 3D Blades delivers big and powerful airflow that instantly makes spaces comfortable and cool.
Note: This table shows values for the airflow rate in high mode.
Cools the Area Quickly

Delivers Cool Air from High Ceilings

A wider main flap and sub-flap increase airflow, and a wider-angle jetting port creates a longer airflow. Cool air can reach from a maximum height of 5 meters, making even spaces with high ceilings and open spaces comfortable.
Note: 4-Way Cassette 3448PU type
Delivers Cool Air from High Ceilings

Cools Every Corner of Spaces

The air delivered in four directions from the wide flap creates a 360 degree airflow, spreading cool air to every corner of spacious environments. Thus, the entire room is cooled, ensuring the comfort of your customers and staff.
Cools Every Corner of Spaces

Double Insulation to Prevent Dew Condensation

The unit prevents water leaks due to condensation. The interior of the indoor unit of the air conditioner is cold, so when it comes into contact with hot air outside, condensation occurs, causing water leaks. Panasonic adopts insulation materials both inside and outside of the unit to guard against condensation and water leaks.
Double Insulation to Prevent Dew Condensation

Flat Horizontal Design That Conditions the Interior

Panasonic believes that one of the most important elements of design is that it doesn’t interfere with the overall room interior. The flat horizontal design of the 4-Way Cassette achieves an elegant yet simple form. This design allows it to protrude only 33.5 mm from the ceiling, to blend naturally into a variety of interiors, including offices and restaurants.
Flat Horizontal Design That Conditions the Interior

Flexible and Easy Installation

The drain pump can pump water up to a height of 850 mm, making the drain pipe layout easy.
A Drain Height of Up to 850 mm from the Ceiling Surface

The unit has been redesigned for easier installation. (1) Previously, the eye bolts were hard to attach because of the bracket’s shape. (2) By improving it to a V-shape, it is easier to install. (3) The nut has become larger, so it is easier to hold.
Easy Installation Design

Specs

S-18PU3HB

Photo of S-18PU3HB

S-2124PU3HB

Photo of S-2124PU3HB

S-3448PU3HB

Photo of S-3448PU3HB
  • Heat PumpHeat Pump
  • nanoe X Generator Mark2nanoe X Generator Mark2
  • Comfort Cloud AppComfort Cloud App
  • InverterInverter
  • CONEXCONEX

nanoe™ X patented air purification technology

nanoe™ X effectiveness proven in large space by 3rd party

CONEX: A next-generation remote control

Industry-leading powerful, 360° wide & comfortable airflow

Powerful drain pump gives 850 mm lift

Wireless remote controller included

S-18PU3HB S-2124PU3HB S-3448PU3HB
Air Volume (Cooling - H) 16.5 m³/min, 275 cfm 21.0/22.0 m³/min, 350/367 cfm 36.0/37.0/38.0 m³/min, 601/617/634 cfm
Air Volume (Cooling - M) 13.5 m³/min, 225 cfm 16.0 m³/min, 267 cfm 26.0/27.0/29.0 m³/min, 434/450/484 cfm
Air Volume (Cooling - L) 11.5 m³/min, 192 cfm 13.0 m³/min, 217 cfm 18.0/19.0/20.0 m³/min, 300/317/334 cfm
Air Volume (Heating - H) 16.5 m³/min, 275 cfm 21.0/22.0 m³/min, 350/367 cfm 36.0/37.0/38.0 m³/min, 601/617/634 cfm
Air Volume (Heating - M) 13.5 m³/min, 225 cfm 13.0/16.0 m³/min, 267/267 cfm 26.0/27.0/29.0 m³/min, 434/450/484 cfm
Air Volume (Heating - L) 11.5 m³/min, 192 cfm 13.0 m³/min, 217 cfm 18.0/19.0/20.0 m³/min, 300/317/334 cfm
Sound Pressure Level (Cooling - H) 32 dB (A) 36/37 dB (A) 45/46/47 dB (A)
Sound Pressure Level (Cooling - M) 29 dB (A) 31 dB (A) 38/39/40 dB (A)
Sound Pressure Level (Cooling - L) 27 dB (A) 28 dB (A) 32/33/34 dB (A)
Sound Pressure Level (Heating - H) 32 dB (A) 36/37 dB (A) 60/61/62 dB (A)
Sound Pressure Level (Heating - M) 29 dB (A) 31 dB (A) 53/54/55 dB (A)
Sound Pressure Level (Heating - L) 27 dB (A) 28 dB (A) 47/48/49 dB (A)
Sound Power Level (Cooling - H) 47 dB 51/52 dB 45/46/47 dB
Sound Power Level (Cooling - M) 44 dB 46 dB 38/39/40 dB
Sound Power Level (Cooling - L) 42 dB 43 dB 32/33/34 dB
Sound Power Level (Heating - H) 47 dB 51/52 dB 60/61/62 dB
Sound Power Level (Heating - M) 44 dB 46 dB 53/54/55 dB
Sound Power Level (Heating - L) 42 dB 43 dB 47/48/49 dB
Dimension (Indoor) H256 x W840 x D840 mm H256 x W840 x D840 mm H319 x W840 x D840 mm
Dimension (Panel) H44 x W950 x D950 mm H44 x W950 x D950 mm H44 x W950 x D950 mm
Net Weight (Indoor) 19 kg 20 kg 25 kg
Net Weight (Panel) 5 kg 5 kg 5 kg