U2 Type: 4-Way Cassette (nanoe X Generator Mark3)
U2 Type 4-way Cassette units have a flat design and a built-in drain pump that allows for flexible installation and design options that blend in with interiors and buildings. They also offer a new level of air quality thanks to the nanoe X Generator Mark3.
Technical Focus
• New high performance turbo fan, new path system for heat exchanger
• Lower noise in slow fan operation
• Industry top lightweight, easy piping
• Easy installation structure of the panel
• ECONAVI: Floor temperature and human sensor added
• Inside cleaning by 100x nanoe™ + dry control
Cooling/Heating |
2.2/2.5 |
2.8/3.2 |
3.6/4.2 |
4.5/5.0 |
5.6/6.3 |
6.0/7.1 |
---|---|---|---|---|---|---|
Cooling/Heating |
7,500/ |
9,600/ |
12,300/ |
15,400/ |
19,100/ |
20,500/ |
Model No. |
S-22MU2E5BN |
S-28MU2E5BN |
S-36MU2E5BN |
S-45MU2E5BN |
S-56MU2E5BN |
S-60MU2E5BN |
Cooling/Heating |
7.3/8.0 |
9.0/10.0 |
11.2/14.0 |
14.0/16.0 |
16.0/18.0 |
---|---|---|---|---|---|
Cooling/Heating |
24,900/ |
30,700/ |
38,200/ |
47,800/ |
54,600/ |
Model No. |
S-73MU2E5BN |
S-90MU2E5BN |
S-112MU2E5BN |
S-140MU2E5BN |
S-160MU2E5BN |
Document
Features
A New Level of Air Quality with nanoe X Generator Mark3
24-hour nanoe™ X Air Protection
Get 24 hours of quality air for you and your loved ones by turning nanoe™ X on using Panasonic Comfort Cloud anywhere, anytime. nanoe™ X functions in both cooling and fan modes and is maintenance-free, helping you enjoy cleaner air while keeping your costs down.
Higher Concentration, Even in Large Space
The amount of hydroxyl radicals generated increased 100 times, compared to the original nanoe™, which achieves greater effectiveness even in large spaces of 112 m².
Conditions of the simulation • Room size: 112 m² • Room height: 2.4 m • Inspection model: 4-Way Cassette • Position of IDU: Centre
Note: The result is based on the conditions for the simulation and it may differ from the concentration measured in an actual room. nanoe™ particles are extremely tiny in nano-meter size. They cannot be seen, so the concentration image is solely for illustrative purposes.
Odour Reduction to 1.8 Level
[Odour intensity] 5: Very strong odour, 4: Strong odour, 3: Easily detectable odour, 2: Weak, recognisable odour (cognitive threshold concentration), 1: Barely detectable odour (detection threshold concentration), 0: No odour
*Testing Overview: [Testing organisation] Panasonic Product Analysis Center [Test method] Verification in a test room (approx. 230 m³ (6.8 x 8.5 x 4.0 m)) using a 6-step odour intensity display method [Method of deodorisation] Operation of a CS-P80U6 equipped with a nanoe X Generator Mark2 and release of nanoe™ [Target] Adhered aging odour (nonenal) [Test Result] Odour intensity reduced to 1.8 in 60 minutes (L19YK032-01) **Testing Overview: [Testing organisation] Panasonic Product Analysis Center [Test method] Verification in a test room (approx. 230 m³ (6.8 x 8.5 x 4.0 m)) using a 6-step odour intensity display method [Method of deodorisation] Operation of a CS-P160U6 equivalent tester equipped with a nanoe X Generator Mark3 and release of nanoe™ [Target] Adhered aging odour (nonenal) [Test Result] Odour intensity reduced to 1.8 in 30 minutes (R21HM003-0)
Internal Cleaning Function to Suppress Mould Growth
After cooling/drying operation, the inside of the indoor unit is automatically dried.* nanoe™ X is activated to suppress mould growth.
*If you wish to set the internal cleaning off, use the wireless remote controller to turn the function off. Please consult an authorized dealer for setting.
Note: The product image shown is for illustration purposes only and may not be an exact representation of the product.
Compact and Flat Horizontal Design
Compact, Modern & Flat Panel Design with Built-in Drain Pump
The horizontal design of the 4-Way Cassette achieves an elegant designed panel. Its slim design allows protruding 33.5 mm from the ceiling. Enhancing the unit’s appeal is a built-in drain pump allowing flexible installation and design options with up to 850 mm lift. Long horizontal piping is also possible.
Flat Horizontal Design
Panasonic believes that one of the most important elements of design is that it doesn’t interfere with the overall room interior. The flat horizontal design of the 4-Way Cassette achieves an elegant yet simple form. This design allows it to protrude only 33.5 mm from the ceiling, to blend naturally into a variety of interiors, including offices and restaurants.
Easy to Clean Suction Grille
Suction grille is able to make 90-degree turns.
Drain Pump of Up to 850 mm from the Ceiling Surface
Built-in drain pump allows flexible installation and design options with up to 850 mm lift. Long horizontal piping is also possible.
Industry-leading Airflow
Powerful Airflow
The Turbo Fan with Twisted 3D Blades provides a large and powerful airflow to cool every corner of the room.
High-Ceiling Installation (Up to 5 m for 11.2 kW and Higher Capacity Models)
The units can be installed in rooms with high ceilings, where they provide ample floor-level heating in the winter.
1. 4-way discharge high ceiling setting 2
2. 3-way discharge with the optional air-blocking materials
3. 2-way discharge with the optional air- blocking materials
*When using the unit in a configuration other than the factory settings, it is necessary to make settings on-site to increase airflow.
**Use air-blocking materials (CZ-CFU3) to completely block two discharge outlets for 2-way airflow.
360° Comfortable Airflow
Air coming out of the centre of the discharge outlets travels farther. Air is discharged across a wide area from the four sides of the unit.
Energy Efficiency
ECONAVI Detects Inefficiencies and Saves Energy
Panasonic Inverter technology and ECONAVI* technology work together to provide extremely energy-efficient cooling or heating. With the optional ECONAVI panel, the cassette has the ability to constantly monitor the conditions of the room, including occupancy levels, adjusting performance accordingly. Enjoy constant comfort with energy-saving performance.
*Optional ECONAVI panel CZ-KPU3A or ECONAVI sensor CZ-CENSC1 are required.
ECONAVI can Be Added without Compromising Aesthetics
A newly put humidity sensor on the air suction part achieves more comfort and energy-saving operation. ECONAVI function operates based on activity amount and comfort and energy saving based on temperature and humidity. It works in case of low humidity during cooling operation and high humidity during heating operation. New circulate function and movement detection improve comfort.
Why Panasonic
Talk to our Air Design Specialists