An image showing that nanoe™ X contains many hydroxyl radicals

More hydroxyl radicals, greater benefits

nanoe™ X technology has evolved dramatically. Compared to the first nanoe™ generator developed by Panasonic in 2003, the nanoe X Generator Mark 2, developed in 2019, generates 20 times and the nanoe X Generator Mark 3, developed in 2021, even generates 100 times as many hydroxyl radicals.

The decisive factor for the cleaning effects is hydroxyl radical amount,
which contained in nanoe™ X particles.

More hydroxyl radicals, greater benefits

nanoe™

nanoe™ X

Generator Mark 1

Generator Mark 2

Generator Mark 3

Hydroxyl radicals

480 billion
hydroxyl radicals/sec.

4.8 trillion
hydroxyl radicals/sec.

9.6 trillion
hydroxyl radicals/sec.

48 trillion
hydroxyl radicals/sec.

Generating
mechanism

Counter electrode
Atomisation electrode
Generating area for hydroxyl radicals: Small

With multi-leader discharge (4 needle-shaped electrodes) the generation area is significantly expanded, so 10 times as many hydroxyl radicals are generated.
Multi-leader discharge (4 needle-shaped electrodes)

The convex shape of the counter electrode draws moisture from the discharge point upward, stabilizing discharge, so 20 times as many hydroxyl radicals are generated.

Electrostatic atomisation Multi-leader discharge (optimised discharge control)
Force to pull water

Round-Leader discharge system that discharges electricity in a circular pattern to increase the area for generating hydroxyl radicals, so 100 times as many hydroxyl radicals are generated.

Discharge
system

Electrostatic atomisation
discharge

Electrostatic atomisation
(Multi-leader discharge)

Electrostatic atomisation
Multi-leader discharge
(optimised discharge control)

Electrostatic atomisation round-leader discharge

Particle size

5-20nm

5-20nm

5-20nm

5-20nm

Particle lifespan

Approx. 600 sec.

Approx. 600 sec.

Approx. 600 sec.

Approx. 600 sec.

Moisture content compared to ordinary negative ion

Approx. 1,000 times

Approx. 1,000 times

Approx. 1,000 times

Approx. 1,000 times

Released

2003

2016

2019

2021

Higher concentration, even in large spaces

Greater effectiveness even in large spaces of more than 100 ㎡.

Higher concentration, even in large spaces

Conditions of the Simulation: Inspection / Model: 4-way cassette / Room size: 112㎡ / Room height: 2.4m / Position of IDU: Centre of space /
Ventilation: 3 times/hour

Evolution of the nanoe™ X Effect

Effectiveness in large space with generator mark 3

Inhibits Virus

An air conditioner equipped with nanoe™ X Generator Mark 3 inhibits activity of adhered virus (Bacteriophage) by 98.81% in 4 hours.

Testing organisation: SGS Inc / Test subject: Adhered Bacteriophage / Test volume: Approx. 139m  large space (6.6×8.9x2.48m)
Test result: Inhibited 98.81% in 4 hours
Test repot no.: SHES210901902583

Test Ambient

 

Test Ambient

Approx.139m3 (1):6.6m  (2):8.9m  (3):2.48m

Test Result

Bacteriophage

Test Result

Deodorise*1*2

An air conditioner equipped with nanoe™ X Generator Mark 3 reduces cigarette smoke odour intensity by 1.7 levels in 30 mins.

Testing organisation: SGS Inc / Test subject: Adhered cigarette smoke odour / Test volume: Approx. 139m  large space (6.6×8.9x2.48m)
Test result: Odour intensity reduced 1.7 levels in 30 mins.
Test repot no.: SHES210901902478

Test Ambient

 

Test Ambient

Approx.139m3 (1):6.6m  (2):8.9m  (3):2.48m

Test Result

Cigarette smoke odour

Test Result

Better deodorisation results than with the
Generator Mark 2

Sweat odour *3

Better deodorisation results than with the Generator Mark 2

Greatly improved deodorisation speed

 

Urine odour *4

Faeces odour *5

Greatly improved deodorisation speed

Odour intensity: 5-Very strong odour 4-Strong odour 3-Easily detectable odour
2-Weak,recognisable odour (cognitive threshold concentration) 1-Barely detectable odour (detection threshold concentration) 0-No odour

Inhibits Pollen

The result of nanoe™ X Generator Mark 3
Inhibits pollen in 1/4 the time of nanoe™ X Generator Mark 2*7

comparison: mark 1, mark 2, mark3 by panasonic

Inhibits Mould

Inhibits mould growth in fans and heat exchangers*6
Internal Cleaning Function
After cooling/drying function, the inside of the indoor unit is automatically dried.

nanoe™ X Operating time

Operations

ON

Air purification with nanoe™ X

OFF

Internal Cleaning Function

Operating Timing

ON

Cooling / Heating / DRY / Fan

OFF

Cool / Dry operation

Dried with a fan to dissipate internal heat

Dried with a fan to dissipate internal heat

Internal circulation of nanoe™ X with a fan

Internal circulation of nanoe™ X with a fan

Results of Mould Inhibition Test

Comparison with and without internal cleaning function.

Results of Mould Inhibition Test

Test Method: A mould sensor from the Laboratory for mold prediction was installed in an indoor unit (CS-P80U7H) and the growth of mould was compared after 9 days of cooling operation (3 hours of cooling operation and 21 hours of shutdown) with and without internal cleaning.
Environmental Conditions: Temperature 25°C, humidity 70%
Testing Organisation: Laboratory for mould prediction
Test Report Nos.: 210804, 210810, 210805, 210811

*1 This is not a proven effect in an actual operating space. The deodorizing effect depends on the size of the operating space, ambient environment (temperature and humidity), operation time, and types of odours absorbed in fibres.
*2 Effectiveness in a test space of approx. 230 m3. The figures are not the results of tests conducted in an actual operating space.
*3 [Testing organisation] Panasonic Product Analysis Center [Test method] Verification in a test room (approx. 230 m3) using a 6-step odour intensity display method [Method of deodorisation] Operation of a CS-P160U6 equivalent tester equipped with a nanoe™ X Generator Mark 3 and release of nanoe™ [Target] Adhered sweat odour (hexanoic acid) [Test result] Odour intensity was reduced to 1.0 in 2 hours (R21HM004-0) [Method of deodorisation] Operation of a CS-P80U6 4-way cassette equipped with a nanoe™ X Generator Mark 2 and release of nanoe™  [Target] Adhered sweat odour (hexanoic acid) [Test Result] Odour intensity was reduced to 3.1 in 2 hours (L19YK032-11)
*4 [Testing organisation] Panasonic Product Analysis Center [Test method] Verification in a test room (approx. 230 m3) using a 6-step odour intensity display method [Method of deodorisation] Operation of a CS-P160U6 equivalent tester equipped with a nanoe™ X Generator Mark 3 and release of nanoe™ [Target] Adhered urine odour (trimethylamine) [Test Result] Odour intensity reduced to 1.0 in 2 hours (R21HM005-0)
*5 [Testing organisation] Panasonic Product Analysis Center [Test method] Verification in a test room (approx. 230 m3) using a 6-step odour intensity display method [Method of deodorisation] Operation of a CS-P160U6 equivalent tester equipped with a nanoe™ X Generator Mark 3 and release of nanoe™  [Target] Adhered faeces odour (methyl mercaptan) [Test Result] Odour intensity reduced to 1.0 in 2 hours (R21HM006-0)
*6 While this function is effective in inhibiting mould growth, it does not prevent mould from occurring. The mould growth inhibition effect may vary depending on the installation environment and operating time. *When using the nanoe™ X Generator Mark 3 function, a multi-function wired remote control (CZ-10RT4C) is required. (The floor-standing type with a built-in control switch in the main unit can be used.) *Only ON/OFF operation is possible with the multilingual wired remote controller (CZ-10RTF4). Also, local setup is required to use the nanoe™ X Generator Mark 3.
*7 Effect after 3 hours in a test space of approx. 24 m3. The figures are not the results of testing in an actual operating space.
*8 <nanoe™ X Generator Mark 1> [Testing organisation] Panasonic Product Analysis Center [Test method] ELISA method of measuring allergens adhering to fabric in a test room (approx. 24 m3) [Method of inhibition] Release of nanoe™ [Target] Adhered allergen (cedar pollen) [Test Result] Inhibition of 99% or more in 24 hours (4AA33-151001-F01) <nanoe™ X Generator Mark 2>
[Testing organisation] Panasonic Product Analysis Center, [Test method] ELISA method of measuring allergens adhering to fabric in a test room (approx. 24 m3) [Method of inhibition] Release of nanoe™ [Target] Adhered allergen (cedar pollen) [Test Result] Inhibition of 99% or more in 12 hours confirmed (L19YA009) <nanoe™ X Generator Mark 3>  [Testing organisation] Panasonic Product Analysis Center [Test method] ELISA method of measuring allergens adhering to fabric in a test room (approx. 24 m3) [Method of inhibition] Release of nanoe™ [Target] Adhered allergen (cedar pollen) [Test Result] Inhibition of 99% or more in 3 hours (H21YA017-1)