Photo of 2.0HP Premium Single Split Inverter Air Conditioner CS-S18RKH (CU-S18RKH)

2.0HP Premium Single Split Inverter Air Conditioner CS-S18RKH (CU-S18RKH)

Model Indoor (50Hz) CS-S18RKH-1
Outdoor (50Hz) CU-S18RKH-1
Refrigerant Type R410A
Cooling Capacity Btu/h 18,000 (3,750-20,500)
kW 5.27 (1.10-6.00)
EER Btu/hW 12.2
Noise Level Indoor (H/L/Q-Lo) (dB-A) 44/32/29
Outdoor (dB-A) (50)
Phase ø 1
Electrical Data Voltage (V) 230
Running Current (A) 6.8
Power Input (W) 1,470 (290-1,700)
Moisture Removal L/h 2.9
Pt/h 6.1
Air Circulation (Indoor/Hi) m3/min. 17.7
ft3/min. 625
Dimensions Height (mm) 296 (619)
Height (inch) 11-21/32 (24-3/8)
Width (mm) 1,070 (824)
Width (inch) 42-5/32 (32-15/32)
Depth (mm) 241 (299)
Depth (inch) 9-1/2 (11-25/32)
Net Weight kg 12 (34)
lb 26 (75)
Refrigerant Pipe Diameter Liquid Side (mm) ø 6.35
Liquid Side (inch) 1/4
Gas Side (mm) ø 12.70
Gas Side (inch) 1/2
Pipe Extension Chargeless Pipe Length (m) 10
Maximum Pipe Length (m) 20
Maximum Elevation Length (m) 15
Additional Refrigerant Gas* (g/m) 15
Power Supply Indoor
Cleaner Air nanoe-G Yes
Odour-Removing Function Yes
Removable, Washable Panel Yes
Comfort iAUTO-X Yes
iAUTO No
ECONAVI Yes
Temperature Wave Yes
AUTOCOMFORT Yes
Inverter Control Yes
Quiet Mode Yes
Soft Dry Operation Mode Yes
Personal Airflow Creation Yes
Airflow Direction Control (Up Down) No
Manual Horizontal Airflow Direction Control No
Manual Airflow Direction Control (Left Right) No
Convenience 24-Hour Dual ON OFF Real Setting Timer Yes
24-Hour ON OFF Real Setting Timer No
LCD Wireless Remote Control Yes
Wired Remote Control No
Reliability Random Auto Restart (32 Restart Patterns) Yes
Blue Fin Condenser Yes
Long Piping (Numbers indicate the maximum pipe length) 20m
Top-Panel Maintenance Access Yes
Self-Diagnostic Function Yes
NOTE Caution For CS-S10/S13/S15/S18/S24/S28RKH-1 (Important) Please do not use copper pipes that are less than 0.6mm in thickness.
*When pipes are not extended from the standard pipe length, the required amount of refrigerant is already in the unit.