Model | Indoor (50Hz) | CS-S13TKH |
---|---|---|
Outdoor (50Hz) | CU-S13TKH | |
Refrigerant Type | R410A | |
Cooling Capacity | (min-max) kW | 3.66 (0.92-4.20) |
(min-max)Btu/h | 12,500 (3,140-14,300) | |
EER | (min-max) Btu/hW | 12.02 (12.08-11.92) |
Electrical Data | Voltage (V) | 230 |
Running Current (A) | 4.8 | |
Power Input (W) | 1,040 (260-1,200) | |
Moisture Removal | L/h | 2.1 |
Pt/h | 4.4 | |
Air Circulation | Indoor m3/min (ft3/min) | 11.1 (390) |
Outdoor m3/min (ft3/min) | 30.9 (1,090) | |
Noise Level | Indoor (H/L/Q-Lo) (dB-A) | 38/28/25 |
Outdoor (H / L) (dB-A) | 48 | |
Dimensions | Height (mm) | 295 (542) |
Height (inch) | 11-5/8 (21-11/32) | |
Width (mm) | 919 (780) | |
Width (inch) | 36-3/16 (30-23/32) | |
Depth (mm) | 199 (289) | |
Depth (inch) | 7-27/32 (11-13/32) | |
Net Weight | kg | 9 (20) |
lb | 27 (60) | |
Refrigerant Pipe Diameter | Liquid Side (mm) | ø 6.35 |
Liquid Side (inch) | 1/4 | |
Gas Side (mm) | ø 12.70 | |
Gas Side (inch) | 1/2 | |
Pipe Extension | Chargeless Pipe Length (m) | 7.5 |
Maximum Pipe Length (m) | 15 | |
Maximum Elevation Length (m) | 5 | |
Additional Refrigerant Gas* (g/m) | 15 | |
Power Supply | Indoor | |
Cleaner Air | nanoe-G | Yes |
Odour-Removing Function | Yes | |
Removable, Washable Panel | Yes | |
Comfort | iAUTO-X | Yes |
iAUTO | No | |
ECONAVI | Yes | |
Temperature Wave | Yes | |
AUTOCOMFORT | Yes | |
Inverter Control | Yes | |
Quiet Mode | Yes | |
Soft Dry Operation Mode | Yes | |
Personal Airflow Creation | Yes | |
Airflow Direction Control (Up Down) | No | |
Manual Horizontal Airflow Direction Control | No | |
Manual Airflow Direction Control (Left Right) | No | |
Convenience | 24-Hour Dual ON OFF Real Setting Timer | Yes |
24-Hour ON OFF Real Setting Timer | No | |
LCD Wireless Remote Control | Yes | |
Wired Remote Control | No | |
Reliability | Random Auto Restart (32 Restart Patterns) | Yes |
Blue Fin Condenser | Yes | |
Long Piping (Numbers indicate the maximum pipe length) | 15m | |
Top-Panel Maintenance Access | Yes | |
Self-Diagnostic Function | Yes | |
NOTE | Caution For CS-S10/S13/S15/S18/S24/S28TKH-1 (Important) Please do not use copper pipes that are less than 0.6mm in thickness. *When pipes are not extended from the standard pipe length, the required amount of refrigerant is already in the unit. |
Copyright © 2024 Panasonic Malaysia Sdn Bhd.