3.0HP Standard Non-Inverter Air Conditioner CS-PV28RKH (CU-PV28RKH)

Model Indoor (50Hz) CS-PV28RKH-1
Outdoor (50Hz) CU-PV28RKH-1
Horse Power HP 3.0
Refrigerant Type R410A
Cooling Capacity Btu/h 27,000
kW 7.92
EER Btu/hW 9.6
Noise Level Indoor (H/L) (dB-A) 50/46
Outdoor (dB-A) (57)
Phase ø 1
Electrical Data Voltage (V) 230
Running Current (A) 13.0
Power Input (W) 2,800
Moisture Removal L/h 4.6
Pt/h 9.7
Air Circulation (Indoor/Hi) m3/min. 20.2
ft3/min. 713
Dimensions Height (mm) 290 (750)
Height (inch) 11-7/16 (29-17/32)
Width (mm) 1,070 (875)
Width (inch) 42-5/32 (34-15/32)
Depth (mm) 240 (345)
Depth (inch) 9-15/32 (13-19/32)
Net Weight kg 12 (56)
lb 26 (123)
Refrigerant Pipe Diameter Liquid Side (mm) ø 6.35
Liquid Side (inch) 1/4
Gas Side (mm) ø 15.88
Gas Side (inch) 5/8
Pipe Extension Chargeless Pipe Length (m) 7.5
Maximum Pipe Length (m) 30
Maximum Elevation Length (m) 20
Additional Refrigerant Gas* (g/m) 30
Power Supply Outdoor
Comfort iAUTO-X No
iAUTO Yes
ECONAVI No
Temperature Wave No
AUTOCOMFORT No
Inverter Control No
Quiet Mode No
Soft Dry Operation Mode Yes
Personal Airflow Creation No
Airflow Direction Control (Up Down) Yes
Manual Horizontal Airflow Direction Control Yes
Automatic Operation Mode (Cooling) Yes
Cleaner Air nanoe-G No
Odour-Removing Function Yes
Removable, Washable Panel Yes
Convenience 24-Hour Dual ON OFF Real Setting Timer No
24-Hour ON OFF Real Setting Timer Yes
LCD Wireless Remote Control Yes
Wired Remote Control No
Reliability Random Auto Restart (32 Restart Patterns) Yes
Blue Fin Condenser Yes
Long Piping (Numbers indicate the maximum pipe length) 30m
Top-Panel Maintenance Access Yes
Self-Diagnostic Function No
NOTE * When pipes are not extended from the standard pipe length, the required amount of refrigerant is already in the unit.