This website ("Site Page") is developed and owned by Panasonic Malaysia Sdn. Bhd. and its affiliates (“Panasonic”, “us”). By accessing the Site Page, you agree to be bound by these Terms and Conditions of Use, the Privacy Statement, and any other terms and legal notices on the Site Page. ok

RM #,###.00 000 false categorybrowsepage,comparepage,wishlistpage,learncontentpage false productpage false 010 //panasonic-malaysia.ibrandiq.com/en/Widgets/Fluid/{0} //panasonic-malaysia.ibrandiq.com/Products/MultipleInStock/Fluid/{0}
Photo of 2.5HP Deluxe Non-Inverter R32 Air Conditioner CS-N24VKH-1

2.5HP Deluxe Non-Inverter R32 Air Conditioner CS-N24VKH-1

Model Indoor (50Hz) CS-N24VKH-1
Outdoor (50Hz) CU-N24VKH-1
Refrigerant Type R32
Cooling Capacity kW 6.85
Btu/h 23,400
EER Btu/hW 10.68
W/W 3.13
CSPF Wh/Wh 3.32
Electrical Data Voltage (V) 230
Running Current (A) 9.7
Power Input (W) 2,190
Moisture Removal L/h 3.9
Pt/h 8.2
Air Circulation Indoor m³/min (ft³/min) 21.5 (759)
Outdoor m³/min (ft³/min) 40.3 (1,420)
Noise Level Indoor (H/L/Q-Lo) (dB-A) 47/42
Outdoor (H / L) (dB-A) 55
Dimensions Height (mm) 302 (619)
Height (inch) 11-29/32 (24-3/8)
Width (mm) 1,102 (824)
Width (inch) 43-13/32 (32-15/32)
Depth (mm) 244 (299)
Depth (inch) 9-5/8 (11-25/32)
Net Weight Indoor kg (lb) 12 (26)
Outdoor kg (lb) 41 (90)
Refrigerant Pipe Diameter Liquid Side (mm) ø 6.35
Liquid Side (inch) ¼
Gas Side (mm) ø 15.88
Gas Side (inch) 5/8
Pipe Extension Chargeless Pipe Length (m) 7.5
Maximum Pipe Length (m) 30
Maximum Elevation Length (m) 20
Additional Refrigerant Gas* (g/m) 25
Power Supply Indoor
Cleaner Air nanoe™X No
nanoe-G Yes
Anti-Dust Coating No
Dust Sensor No
Odour-Removing Function Yes
Removable, Washable Panel Yes
Comfort Radiant Cooling No
iAUTO-X No
ECONAVI No
Temperature Wave No
SLEEP Yes
Inverter Control No
iAUTO Yes
Quiet Mode Yes
Soft Dry Operation Mode Yes
Personal Airflow Creation Yes
Airflow Direction Control (Up Down) No
Manual Horizontal Airflow Direction Control No
Convenience 24-Hour Dual ON OFF Real Setting Timer No
24-Hour ON OFF Real Setting Timer Yes
LCD Wireless Remote Control Yes
Wireless LAN Remote Control For Internet Connection No
Wired Remote Control No
Reliability Random Auto Restart (32 Restart Patterns) Yes
Blue Fin Condenser Yes
Long Piping (Numbers indicate the maximum pipe length) 30m
Top-Panel Maintenance Access Yes
Self-Diagnostic Function No
NOTE Caution For CS-N9/N12/N18/N24/N28VKH-1 (Important) Please do not use copper pipes that are less than 0.6mm in thickness.
* When pipes are not extended from the standard pipe length, the required amount of refrigerant is already in the unit.

This website ("Site Page") is developed and owned by Panasonic Malaysia Sdn. Bhd. and its affiliates (“Panasonic”, “us”). By accessing the Site Page, you agree to be bound by these Terms and Conditions of Use, the Privacy Statement, and any other terms and legal notices on the Site Page. ok