R32 Inverter NX Series Standard
Good energy-saving performance, compact, and resistant to high temperatures and rust
R32 Inverter NX Series Standard delivers energy efficiency through its energy-saving performance and design. With the ability to fit into any space or layout, these outdoor units ensure powerful operation.
Please Select Your User Type
R32 Inverter NX Series Standard
Specs
- Inverter
- R32 Refrigerant
Next generation R32 refrigerant
3-phase lineup (43/48k)
3 wire method
Operating range expanded up to outdoor air temperature of 46 °C
In-house manufactured compressor
Blue fin condenser
Documents
- R32 Inverter NX Series Standard 4-Way Cassette Operating Instructions EN VI (PDF - 5.4 MB)
- R32 Inverter NX Series Standard Ceiling Exposed Operating Instructions EN VI (PDF - 2.9 MB)
- R32 Inverter NX Series Standard Adaptive Ducted Operation Instruction EN VI (PDF - 1.8 MB)
- R32 Inverter NX Series Standard Installation Instructions EN (PDF - 761 KB)
Combination
Case Studies
Features
Btu/h (rated) |
17,100 |
20,500 |
24,200 |
27,600/29,000 |
34,100 |
42,700 |
45,500/47,800 |
42,700 |
45,500/47,800 |
|
Phase |
1Φ Phase |
1Φ Phase |
1Φ Phase |
3Φ Phase |
||||||
4-Way Cassette |
|
S-1821PU3H |
S-2430PU3H |
S-3448PU3H |
S-3448PU3H |
|||||
Adaptive Ducted |
|
S-1821PF3H |
S-2430PF3H |
S-3448PF3H |
S-3448PF3H |
|||||
Celling Exposed |
|
S-1821PT3H |
S-2430PT3H |
S-3448PT3H |
S-3448PT3H |
|||||
Outdoor Unit |
|
U-18PR1H5 |
U-21PR1H5 |
U-24PR1H5 |
U-30PR1H5 |
U-34PR1H5 |
U-43PR1H5 |
U-48PR1H5 |
U-43PR1H8 |
U-48PR1H8 |
Saves 90 USD on Annual Electricity Bill
The Inverter Standard model, which operates more efficiently, is more expensive than the Non-Inverter model, but it saves 90 USD on your annual electricity bill by reducing annual power consumption by about 42%.* If you plan to run your air conditioner for extended periods of time, the Inverter Standard model is by far the best value.
*Based on comparative tests of the following Panasonic products: R32 Inverter NX Series Standard (S-2430PU3H/U-24PR1H5) and R32 Non-Inverter (S-25PU1H5B/U-25PN1H5).
Note: Annual energy consumption is calculated based on ISO16358-1. Operating hours: 8 hours per day x 240 days =1,920 hours. Electricity Bill: 0.18USD/kWh, referring to Electricity of Cambodia.
Note: Annual energy consumption is calculated based on ISO16358-1. Operating hours: 8 hours per day x 240 days =1,920 hours. Electricity Bill: 0.18USD/kWh, referring to Electricity of Cambodia.
Eco-Friendly R32 Refrigerant
Panasonic air conditioners are increasingly using the eco-friendly R32 refrigerant, an excellent energy- and cost-efficient heat transfer medium. With lower global warming potential, the R32 refrigerant is much more environmentally friendly.
・ Higher Cooling Capacity
・ Reduce Energy Costs
・ Eco Friendly
・ Higher Cooling Capacity
・ Reduce Energy Costs
・ Eco Friendly
High Durable Outdoor Unit
Stable Operation Even in Hot Weather
The operating range has been increased to an outdoor air temperature of up to 46°C. Hot air is discharged from the outdoor unit during cooling operation. Needless to say, if outdoor units are close together, the temperature at the place where the outdoor units have been installed will be higher than the outside temperature. Units in this series continue to operate well even under the high temperature environment of midsummer.
Prevents Unit Stoppages Due to Short Circuits Caused by Geckos
One of the common causes of failures of the outdoor unit is electrical short circuits caused by geckos entering the unit. The unit eliminates gaps that prevent geckos from entering the internal PCB and thus prevent operation stoppages.
In-House Manufactured Compressor with Outstanding Durability
Compressors are the heart of the air conditioner. Panasonic takes responsibility for the manufacture of all of its own products to ensure their durability.
Rust-resistant and Easy to Maintain
Panasonic heat exchangers feature Blue Fin technology to prevent corrosion and ensure long-lasting performance. Panasonic uses a copper tube condenser, which makes it easy to repair and maintain.
Note: Selecting this unit does not completely eliminate the possibility of rust developing. For details concerning unit installation and maintenance, please consult an authorised dealer.
Long Piping Allows Flexible Installation
Piping can be extended up to 30 m without additional gas charging, and up to 50 m with additional gas charging. Even in stores and offices where space is limited, outdoor units can be installed on rooftops and other places.
Note: Additional gas is required when the piping length is extended. *Support for U-30PR1H5-1, U-34PR1H5-1, U-43PR1H5-1, U-43PR1H8-1, U-48PR1H5-1, U-48PR1H8-1 **Support for U-30PR1H5-1, U-34PR1H5-1, U-43PR1H5-1, U-43PR1H8-1, U-48PR1H5-1, U-48PR1H8-1
Flexible and Easy Installation
Piping can be extended up to 30 m without additional gas charging, and up to 50 m with additional gas charging. Even in stores and offices where space is limited, outdoor units can be installed on rooftops and other places.
Note: Additional gas is required when the piping length is extended. *Support for U-30PR1H5-1, U-34PR1H5-1, U-43PR1H5-1, U-43PR1H8-1, U-48PR1H5-1, U-48PR1H8-1 **Support for U-30PR1H5-1, U-34PR1H5-1, U-43PR1H5-1, U-43PR1H8-1, U-48PR1H5-1, U-48PR1H8-1
Panasonic outdoor units are designed to be compact enough to fit into any layout.
This series have been developed with 3 wire power and communication. It makes it simple and easy to replace old systems with 3 wire connections, which is prevalent in many systems.