R32 Inverter NX Series Deluxe

SHOP NOW

R32 Inverter NX Series Deluxe

Excellent energy-saving performance, compact, and resistant to heat and rust

R32 Inverter NX Series Deluxe delivers superior energy efficiency through its energy-saving performance and design. With the ability to fit into any space or layout, these outdoor units guarantee powerful operation even in extremely hot environments.
  • Inverter
  • R32 Refrigerant
Zoom In
Zoom Out
Close
R32 Inverter NX Series Deluxe

Features

Btu/h (rated)

17,100

20,500

24,200

34,100

42,700

47,800

42,700

47,800

Phase

1Ø Phase

1Ø Phase

1Ø Phase

3Ø Phase

4-Way Cassettes

S-1821PU3HA

S-2430PU3HA

S-3448PU3HA

S-3448PU3HA

Adaptive Ducted

S-1821PF3H

S-2430PF3H

S-3448PF3H

S-3448PF3H

Celling Suspended

S-1821PT3H

S-2430PT3H

S-3448PT3H

S-3448PT3H

Outdoor Unit

U-18PRH1H5

U-21PRH1H5

U-24PRH1H5

U-34PRH1H5

U-43PRH1H5

U-48PRH1H5

U-43PRH1H8

U-48PRH1H8

Saves 104 USD on Annual Electricity Bill

Saves 104 USD on Annual Electricity Bill
The Inverter Deluxe model, which operates more efficiently, is more expensive than the Non-Inverter model, but it saves 104 USD on your annual electricity bill by reducing annual power consumption by about 48%.* If you plan to run your air conditioner for extended periods of time, the Inverter Deluxe model is by far the best value.
*Based on comparative tests of the following Panasonic products: R32 Inverter NX Series Deluxe (S-2430PU3HA/U-24PRH1H5) and R32 Non-Inverter (S-25PU1H5B/U-25PN1H5).​

Note: Annual energy consumption is calculated based on ISO16358-1. Operating hours: 8 hours per day x 240 days =1,920 hours. Electricity Bill: 0.18USD/kWh, referring to Electricity of Cambodia.

Eco-Friendly R32 Refrigerant

Panasonic air conditioners are increasingly using the eco-friendly R32 refrigerant, an excellent energy- and cost-efficient heat transfer medium. With lower global warming potential, the R32 refrigerant is much more environmentally friendly.

・ Higher Cooling Capacity
・ Reduce Energy Costs
・ Eco Friendly
Eco-Friendly R32 Refrigerant

High Durable Outdoor Unit

Stable Operation Even in Scorching Weather

The operating range has been increased to an outdoor air temperature of up to 52°C. Hot air is discharged from the outdoor unit during cooling operation. Needless to say, if outdoor units are close together, the temperature at the place where the outdoor units have been installed will be higher than the outside temperature. Units in this series continue to operate well even under the high temperature environment of midsummer.
Stable Operation Even in Scorching Weather

Prevents Unit Stoppages Due to Short Circuits Caused by Geckos

One of the common causes of failures of the outdoor unit is electrical short circuits caused by geckos entering the unit. The unit eliminates gaps that prevent geckos from entering the internal PCB and thus prevent operation stoppages.
Prevents Unit Stoppages Due to Short Circuits Caused by Geckos

In-House Manufactured Compressor with Outstanding Durability

Compressors are the heart of the air conditioner. Panasonic takes responsibility for the manufacture of all of its own products to ensure their durability.
In-House Manufactured Compressor with Outstanding Durability

Rust-resistant and Easy to Maintain

Panasonic heat exchangers feature Blue Fin technology to prevent corrosion and ensure long-lasting performance. Panasonic uses a copper tube condenser, which makes it easy to repair and maintain.
Note: Selecting this unit does not completely eliminate the possibility of rust developing. For details concerning unit installation and maintenance, please consult an authorised dealer.
Rust-resistant and Easy to Maintain

Long Piping Allows Flexible Installation

Piping can be extended up to 30 m without additional gas charging, and up to 50 m with additional gas charging. Even in stores and offices where space is limited, outdoor units can be installed on rooftops and other places.
Note: Additional gas is required when the piping length is extended.
Long Piping Allows Flexible Installation

Flexible and Easy Installation

Piping can be extended up to 30 m without additional gas charging, and up to 50 m with additional gas charging. Even in stores and offices where space is limited, outdoor units can be installed on rooftops and other places.
Note: Additional gas is required when the piping length is extended.
Long Piping Allows Flexible Installation

Panasonic outdoor units are designed to be compact enough to fit into any layout.
A Compact Outdoor Unit for Places Where Space Is Limited

This series have been developed with 3 wire power and communication. It makes it simple and easy to replace old systems with 3 wire connections, which is prevalent in many systems.
3 Wire Method for Absolute Ease of Refurbishment

Specs

U-18PRH1H5

Photo of U-18PRH1H5

U-21PRH1H5

Photo of U-21PRH1H5

U-24PRH1H5

Photo of U-24PRH1H5

U-34PRH1H5

Photo of U-34PRH1H5

U-43PRH1H5

Photo of U-43PRH1H5

U-48PRH1H5

Photo of U-48PRH1H5

U-43PRH1H8

Photo of U-43PRH1H8

U-48PRH1H8

Photo of U-48PRH1H8
  • InverterInverter
  • R32 RefrigerantR32 Refrigerant

High energy efficiency: COP 4.15 (average of 4-Way Cassette)

Next generation R32 refrigerant

The operating range expanded up to an outdoor air temperature of 52 °C

3-phase lineup (43/48k)

In-house manufactured compressor

Blue fin condenser

U-18PRH1H5 U-21PRH1H5 U-24PRH1H5 U-34PRH1H5 U-43PRH1H5 U-48PRH1H5 U-43PRH1H8 U-48PRH1H8
Sound Pressure Level 50 dB (A) 51 dB (A) 53 dB (A) 54 dB (A) 57 dB (A) 58 dB (A) 57 dB (A) 58 dB (A)
Sound Power Level 69 dB 70 dB 72 dB 73 dB 76 dB 77 dB 76 dB 77 dB
Dimension H695 x W875 x D320 mm H695 x W875 x D320 mm H695 x W875 x D320 mm H996 x W980 x D370 mm H996 x W980 x D370 mm H996 x W980 x D370 mm H996 x W980 x D370 mm H996 x W980 x D370 mm
Net Weight 39 kg 39 kg 39 kg 69 kg 69 kg 75 kg 67 kg 73 kg
Piping Connection (Gas Pipe) 12.70 mm (1/2 inch) 12.70 mm (1/2 inch) 15.88 mm (5/8 inch) 15.88 mm (5/8 inch) 15.88 mm (5/8 inch) 15.88 mm (5/8 inch) 15.88 mm (5/8 inch) 15.88 mm (5/8 inch)
Piping Connection (Liquid Pipe) 6.35 mm (1/4 inch) 6.35 mm (1/4 inch) 9.52 mm (3/8 inch) 9.52 mm (3/8 inch) 9.52 mm (3/8 inch) 9.52 mm (3/8 inch) 9.52 mm (3/8 inch) 9.52 mm (3/8 inch)
Pipe Length (Min-Max) 5-50 m 5-50 m 5-50 m 5-50 m 5-50 m 5-50 m 5-50 m 5-50 m
Elevation Difference 30 m 30 m 30 m 30 m 30 m 30 m 30 m 30 m
Maximum Chargeless Length (Max) 30 m 30 m 30 m 30 m 30 m 30 m 30 m 30 m
Additional Gas 15 g/m 15 g/m 25 g/m 25 g/m 25 g/m 25 g/m 25 g/m 25 g/m
Operation Range, Outdoor (Min-Max) 16-52 °C 16-52 °C 16-52 °C 16-52 °C 16-52 °C 16-52 °C 16-52 °C 16-52 °C

Documents

Combination