Non-Inverter Floor Standing

SHOP NOW

Non-Inverter Floor Standing

Easy to install and maintain

Non-Inverter Floor Standing units are easy to install and easy to clean.
Zoom In
Zoom Out
Close
Non-Inverter Floor Standing

Features

Btu/h (rated)

17,400-17,600

24,600-25,000

24,600

41,000-42,700

Phase

1Ø Phase

1Ø Phase

3Ø Phase

3Ø Phase

Indoor Unit

CS-C18FFH-E

CS-C28FFH-E

CS-C28FFH8-E

CS-C45FFH-E

Outdoor Unit

CU-C18FFH-E

CU-C28FFH-E

CU-C28FFH8-E

CU-C45FFH-E

Airflow Creates a Comfortable and Cool Environment

Cools the Area Quickly

Powerful airflow instantly makes spaces comfortable and cool.
Note: This table shows values for the airflow rate in high mode.
Cools the Area Quickly

Delivers Cool Air Over a Long Distance

Cool air can reach up to a distance of 11 meters, so even deep and wide spaces are comfortable.
Delivers Cool Air Over a Long Distance

Cools Spaces in Their Entirety

The direction of the louvers can be adjusted up, down, left and right.* You can choose to distribute cool air to every part of a large space or deliver cool air to only places where you want it to go. You can use the unit in any way you like.
*Manual setting.
Cools Spaces in Their Entirety

Auto Fan Mode Adjusts to Suit Your Environment

When the auto fan mode is set, the indoor unit of the air conditioner automatically is adjusted the suitable fan speed according to factors such as load.
Auto Fan Mode Adjusts to Suit Your Environment

Excellent Design and Operability

Stylish Design with New Control Panel

Stylish design and easy-to-use operation panel.
Stylish Design with New Control Panel

Random Auto Restart for After Power Outage

When there is a power outage, it automatically restarts the operating that was in progress before power was lost.
Random Auto Restart for After Power Outage

Flexible and Efficient Timer Settings to Meet Your Needs

You can set the start and stop time to within 12 hours from the current time, and use the system flexibly according to your business needs, such as automatic on to maintain a cool and comfortable office environment, or automatic off to prevent forgetting to turn the system off.
Flexible and Efficient Timer Settings to Meet Your Needs

Specs

CS-C18FFH-E_CU-C18FFH-E

Photo of CS-C18FFH-E_CU-C18FFH-E

CS-C28FFH-E_CU-C28FFH-E

Photo of CS-C28FFH-E_CU-C28FFH-E

CS-C28FFH8-E_CU-C28FFH8-E

Photo of CS-C28FFH8-E_CU-C28FFH8-E

CS-C45FFH-E_CU-C45FFH-E

Photo of CS-C45FFH-E_CU-C45FFH-E

Random auto restart (2/3 HP)

Auto fan mode

Self-diagnostic function (5 HP)

Anti-freezing control (2/3 HP)

Wireless remote controller included

CS-C18FFH-E_CU-C18FFH-E CS-C28FFH-E_CU-C28FFH-E CS-C28FFH8-E_CU-C28FFH8-E CS-C45FFH-E_CU-C45FFH-E
Power Source 220-240 V, 1 phase - 50 Hz 220-240 V, 1 phase - 50 Hz 380 V, 3 phase - 50 Hz 380-415 V, 3 phase - 50 Hz
Indoor CS-C18FFH-E CS-C28FFH-E CS-C28FFH8-E CS-C45FFH
Outdoor CU-C18FFH-E CU-C28FFH-E CU-C28FFH8-E CU-C45FFH
Cooling Capacity 5.10-5.15 kW, 17,400-17,600 Btu/h 7.20-7.30 kW, 24,600-25,000 Btu/h 7.20 kW, 24,600 Btu/h 12.00-12.50 kW, 41,000-42,700 Btu/h
Current 8.7-8.8 A 11.9-12.0 A 4.5 A 8.4 A
Power Input 1.90-1.95 kW 2.60-2.65 kW 2.5 kW 4.71-4.80 kW
EER 2.68-2.64 W/W, 9.15-9.02 Btu/hW 2.76-2.75 W/W, 9.46-9.43 Btu/hW 2.88 W/W, 9.84 Btu/hW 2.54-2.60 W/W, 8.70-8.89 Btu/hW
Moisture Removal 2.8 L/h, 5.9 Pt/h 4.2 L/h, 8.9 Pt/h 4.2 L/h, 8.9 Pt/h 7.5 L/h, 15.8 Pt/h
Indoor Unit: Air Circulation 14.5-15.5 m³/min 15.0-16.2 m³/min 15.0 m³/min 27.0 m³/min
Indoor Unit: Noise Level (Hi/Lo) (46/40)-(47/41) dB (A) (48/42)-(49/43) dB (A) 48/43 dB (A) 53/47 dB (A)
Indoor Unit: Dimension H1,680 × W500 × D298 mm H1,680 × W500 × D298 mm H1,680 × W500 × D298 mm H1,880 × W600 × D350 mm
Indoor Unit: Net Weight 34 kg 35 kg 35 kg 52 kg
Outdoor Air Circulation 31.0-32.0 m³/min 56.0-60.0 m³/min 56.0 m³/min 92.0 m³/min
Outdoor Unit: Noise Level 53-54 dB (A) 53-54 dB (A) 53 dB (A) 57 dB (A)
Outdoor Unit: Dimension H540 x W780 x D289 mm H795 x W900 x D320 mm H795 x W900 x D320 mm H1,175 x W900 x D320 mm
Outdoor Unit: Net Weight 40 kg 55 kg 55 kg 88 kg
Outdoor Unit: Refrigerant Pipe Diameter (Gas Side) 12.70 mm (1/2 inch) 15.88 mm (5/8 inch) 15.88 mm (5/8 inch) 19.05 mm (3/4 inch)
Outdoor Unit: Refrigerant Pipe Diameter (Liquid Side) 6.35 mm (1/4 inch) 9.52 mm (3/8 inch) 9.52 mm (3/8 inch) 9.52 mm (3/8 inch)
Outdoor Unit: Pipe Length (Max) 10.0 m 15.0 m 15.0 m 30 m
Outdoor Unit: Elevation Difference (Max) 7.0 m 10.0 m 10.0 m 20 m
Outdoor Unit: Maximum Chargeless Pipe Length (Max) 7.0 m 7.0 m 7.0 m 15.0 m
Outdoor Unit: Additional Refrigerant Gas* 25 g/m 30 g/m 30 g/m 50 g/m
Power Supply Indoor Indoor Outdoor Outdoor
Note *When pipes are not extended from the chargeless pipe length, the required amount of refrigerant is already in the unit. *When pipes are not extended from the chargeless pipe length, the required amount of refrigerant is already in the unit. *When pipes are not extended from the chargeless pipe length, the required amount of refrigerant is already in the unit. *When pipes are not extended from the chargeless pipe length, the required amount of refrigerant is already in the unit.

Documents