Local Adaptor for ON/OFF Control

CZ-CAPC4

Interface Adapter for ERV or 3rd Party Control

Control of individual ERV units, as well as external electrical devices up to 240V AC, 10A, is achievable through contact signals. One unit can control up to three devices.
Close
Zoom In
Zoom Out

Specifications

CZ-CAPC4

Photo of CZ-CAPC4

Maximum of three digital output channels.

Compatible units include lighting systems, ceiling fans, ERVs, and third-party ERV units.

The contact signal controls individual ERV units.

The contact signal enables the control for external electrical devices up to 240V AC, 10A.

Case Studies

Features

On/Off Control of ERV and Other Equipment

Each individual ERV unit (or any external electrical device up to 240V AC, 10A) can be controlled via contact signals through a centralized controller. With a maximum of three digital output channels, a single CZ-CAPC4 can manage the on/off functions of up to three ERV units.
1) Intelligent controller, CZ-256ESMC3

Note: When connecting to our central controller, please pay attention to the operation screen content. Consult with an authorized Panasonic distributor for assistance.
On/Off Control of ERV and Other Equipment

Control of Damper Opening/Closing, Power On/Off, and Air Volume Hi/Low Settings of ERV

Control of the damper's opening and closing, the on/off switch, and the high/low air volume settings of an ERV is possible through a centralized controller.
1) Intelligent controller, CZ-256ESMC3

Note: When connecting to our central controller, please pay attention to the operation screen content. Consult with an authorized Panasonic distributor for assistance.
Control of Damper Opening/Closing, Power On/Off, and Air Volume Hi/Low Settings of ERV