Concentrated Airflow, Further
Further and faster airflow across the room.
2 Independent Motors*
The AEROWINGS is controlled by 2 independent motors and dual independent flaps. Airflow is
delivered at a faster pace, spreading further at a concentrated level.
1. 2 Independent Motors
Control the Sub-Flap and Bigger Outer Flap separately.
2. Sub-Flap
Compresses and concentrates cool air.
3. Bigger Outer Flap
Helps to deliver airflow further.
Shower Cooling
Shower airflow spreads fast, cool and concentrated air across room and to the
wall, then showers down gently.
Shower Cooling Airflow Assessment
Airflow Smoke Test
AEROWINGS directs airflow upwards over a wider area then showers down gently and evenly across the room.
Temperature Distribution Test
AEROWINGS directs cool air further and higher towards the ceiling to avoid direct cooling.
Top Air Intake
Hot air is drawn in from the top and cool air is discharged from the bottom to facilitate cool air showering down over the entire area.
Fast Cooling
AEROWINGS twin flaps direct concentrated airflow downwards to cool you rapidly.
Fast Cooling Airflow Assessment
Airflow Smoke Test
AEROWINGS directs airflow downwards and towards you for instant cooling.
Temperature Distribution Test: (Conventional Cooling)
Slow cooling will result in uneven cooling.
Temperature Distribution Test:(Fast Cooling)
Concentrated airflow cools instantly. A room is evenly cooled.
POWERFUL Mode for Instant Cooling Comfort**
Enjoy faster cooling with just a push of a button
POWERFUL Mode will run both the compressor and indoor fan at super high speed, so you get to enjoy powerful cooling.
POWERFUL cooling at startup
POWERFUL Mode cools your room faster by 18%* the moment you switch on your air conditioner.Enjoy cooling comfort instantly, even on a hot day.
* Comparison of Powerful Cool Mode & normal cool mode by using 1.5HP Inverter Model
POWERFUL Cool Mode:
POWERFUL Mode, Outside temperature : 35°C/24°C
Remote setting temperature : 25°C, with Fan Speed : Powerful.
Horizontal Airflow direction : Middle
Vertical Airflow direction : Straight
Normal Cool Mode:
Cool Mode, Outside temperature : 35°C/24°C
Remote setting temperature : 25°C, with Fan Speed : High.
Horizontal Airflow direction : Middle
Vertical Airflow direction : Straight
Total time needed to cool down the room from 35°C to 29°C is measured.
At Panasonic Amenity Room (size : 16.6㎡)
The effect differs according to conditions in installation and usage.
Disclaimer
* Design may vary according to models.
** Applicable for models with POWERFUL mode function.