Retail Sales Price: Panasonic Online Price: SHOP NOW SHOP NOW WHERE TO BUY Buy from Panasonic Where to Buy Out of Stock at Panasonic Online false false false

F3 Type Mid Static Adaptive Ducted

F3 Type Mid Static Adaptive Ducted (Mark3)

Flexible installation design including vertical installation, and excellent air purification functionality

F3 Type Mid Static Adaptive Ducted units are slim and boast excellent performance, making them ideal for installation environments with low ceilings and vertical installations. They also offer the next level of air quality thanks to the nanoe X Generator Mark3, effective even in large spaces.
  • nanoe X Generator Mark3
  • ECONAVI
  • R410A
Zoom In
Zoom Out
Close
F3 Type Mid Static Adaptive Ducted (Mark3)

Specs

S-22MF3E5AN

Photo of S-22MF3E5AN

S-28MF3E5AN

Photo of S-28MF3E5AN

S-36MF3E5AN

Photo of S-36MF3E5AN

S-45MF3E5AN

Photo of S-45MF3E5AN

S-56MF3E5AN

Photo of S-56MF3E5AN

S-60MF3E5AN

Photo of S-60MF3E5AN

S-73MF3E5AN

Photo of S-73MF3E5AN

S-90MF3E5AN

Photo of S-90MF3E5AN

S-112MF3E5AN

Photo of S-112MF3E5AN

S-140MF3E5AN

Photo of S-140MF3E5AN

S-160MF3E5AN

Photo of S-160MF3E5AN
  • nanoe X Generator Mark3nanoe X Generator Mark3
  • ECONAVIECONAVI
  • R410AR410A
  • DC motorDC motor

Flexible installation with horizontal/vertical mounting and rear/bottom air inlet

Space saving 250 mm height

DC fan motor for variable external static pressure control up to 150 Pa

Industry-leading low sound levels from 20 dB (A)

Improved drain pan suitable for both horizontal/vertical installation

nanoe™ X: 100 times more nanoe™ particle for wide commercial space

S-22MF3E5AN S-28MF3E5AN S-36MF3E5AN S-45MF3E5AN S-56MF3E5AN S-60MF3E5AN S-73MF3E5AN S-90MF3E5AN S-112MF3E5AN S-140MF3E5AN S-160MF3E5AN
Power Source 220/230/240 V, 1 phase - 50/60 Hz 220/230/240 V, 1 phase - 50/60 Hz 220/230/240 V, 1 phase - 50/60 Hz 220/230/240 V, 1 phase - 50/60 Hz 220/230/240 V, 1 phase - 50/60 Hz 220/230/240 V, 1 phase - 50/60 Hz 220/230/240 V, 1 phase - 50/60 Hz 220/230/240 V, 1 phase - 50/60 Hz 220/230/240 V, 1 phase - 50/60 Hz 220/230/240 V, 1 phase - 50/60 Hz 220/230/240 V, 1 phase - 50/60 Hz
Cooling Capacity 2.2 kW, 7,500 Btu/h 2.8 kW, 9,600 Btu/h 3.6 kW, 12,300 Btu/h 4.5 kW, 15,400 Btu/h 5.6 kW, 19,100 Btu/h 6.0 kW, 20,500 Btu/h 7.3 kW, 24,900 Btu/h 9.0 kW, 30,700 Btu/h 11.2 kW, 38,200 Btu/h 14.0 kW, 47,800 Btu/h 16.0 kW, 54,600 Btu/h
Heating Capacity 2.5 kW, 8,500 Btu/h 3.2 kW, 10,900 Btu/h 4.2 kW, 14,300 Btu/h 5.0 kW, 17,100 Btu/h 6.3 kW, 21,500 Btu/h 7.1 kW, 24,200 Btu/h 8.0 kW, 27,300 Btu/h 10.0 kW, 34,100 Btu/h 12.5 kW, 42,700 Btu/h 16.0 kW, 54,600 Btu/h 18.0 kW, 61,400 Btu/h
Power Input (Cooling) 0.06/0.06/0.06 kW 0.06/0.06/0.06 kW 0.06/0.06/0.06 kW 0.06/0.06/0.06 kW 0.089/0.089/0.089 kW 0.079/0.079/0.079 kW 0.079/0.079/0.079 kW 0.136/0.136/0.136 kW 0.265/0.265/0.265 kW 0.265/0.265/0.265 kW 0.330/0.330/0.330 kW
Power Input (Heating) 0.06/0.06/0.06 kW 0.06/0.06/0.06 kW 0.06/0.06/0.06 kW 0.06/0.06/0.06 kW 0.089/0.089/0.089 kW 0.079/0.079/0.079 kW 0.079/0.079/0.079 kW 0.136/0.136/0.136 kW 0.265/0.265/0.265 kW 0.265/0.265/0.265 kW 0.330/0.330/0.330 kW
Running Current (Cooling) 0.46/0.45/0.44 A 0.46/0.45/0.44 A 0.46/0.45/0.44 A 0.46/0.45/0.44 A 0.65/0.63/0.61 A 0.53/0.52/0.51 A 0.53/0.52/0.51 A 0.92/0.90/0.88 A 1.80/1.76/1.72 A 1.80/1.76/1.72 A 2.22/2.14/2.09 A
Running Current (Heating) 0.46/0.45/0.44 A 0.46/0.45/0.44 A 0.46/0.45/0.44 A 0.46/0.45/0.44 A 0.65/0.63/0.61 A 0.53/0.52/0.51 A 0.53/0.52/0.51 A 0.92/0.90/0.88 A 1.80/1.76/1.72 A 1.80/1.76/1.72 A 2.22/2.14/2.09 A
Fan Type Sirocco Fan Sirocco Fan Sirocco Fan Sirocco Fan Sirocco Fan Sirocco Fan Sirocco Fan Sirocco Fan Sirocco Fan Sirocco Fan Sirocco Fan
Cooling Air Flow Rate (H/M/L) 768/660/480 m³/h, 213/183/133 L/s 768/660/480 m³/h, 213/183/133 L/s 840/720/480 m³/h, 233/200/133 L/s 840/720/480 m³/h, 233/200/133 L/s 960/840/600 m³/h, 267/233/167 L/s 1,260/1,080/900 m³/h, 350/300/250 L/s 1,260/1,080/900 m³/h, 350/300/250 L/s 1,500/1,380/960 m³/h, 417/383/267 L/s 2,220/1,920/1,560 m³/h, 617/533/433 L/s 2,220/1,920/1,560 m³/h, 617/533/433 L/s 2,400/2,040/1,680 m³/h, 667/567/467 L/s
Heating Air Flow Rate (H/M/L) 840/720/480 m³/h, 233/200/133 L/s 840/720/480 m³/h, 233/200/133 L/s 840/720/480 m³/h, 233/200/133 L/s 840/720/480 m³/h, 233/200/133 L/s 960/840/600 m³/h, 267/233/167 L/s 1,260/1,080/900 m³/h, 350/300/250 L/s 1,260/1,080/900 m³/h, 350/300/250 L/s 1,500/1,380/960 m³/h, 417/383/267 L/s 2,220/1,920/1,560 m³/h, 617/533/433 L/s 2,220/1,920/1,560 m³/h, 617/533/433 L/s 2,400/2,040/1,680 m³/h, 667/567/467 L/s
Fan Motor Output 0.107 kW 0.107 kW 0.107 kW 0.107 kW 0.107 kW 0.165 kW 0.165 kW 0.165 kW 0.259 kW 0.259 kW 0.259 kW
External Static Pressure 30 Pa (10-150 Pa) 30 Pa (10-150 Pa) 30 Pa (10-150 Pa) 30 Pa (10-150 Pa) 30 Pa (10-150 Pa) 30 Pa (10-150 Pa) 30 Pa (10-150 Pa) 40 Pa (10-150 Pa) 50 Pa (10-150 Pa) 50 Pa (10-150 Pa) 50 Pa (10-150 Pa)
Sound Power Level (H/M/L) 54/51/43 dB 54/51/43 dB 54/51/43 dB 54/51/43 dB 58/55/47 dB 54/51/46 dB 54/51/46 dB 58/56/48 dB 64/59/55 dB 64/59/55 dB 66/60/56 dB
Sound Pressure Sound (H/M/L) 31/28/20 dB (A) 31/28/20 dB (A) 31/28/20 dB (A) 31/28/20 dB (A) 35/32/24 dB (A) 31/28/23 dB (A) 31/28/23 dB (A) 35/33/25 dB (A) 41/36/32 dB (A) 41/36/32 dB (A) 43/37/33 dB (A)
Dimension H250 x W800 x D730 mm H250 x W800 x D730 mm H250 x W800 x D730 mm H250 x W800 x D730 mm H250 x W800 x D730 mm H250 x W1,000 x D730 mm H250 x W1,000 x D730 mm H250 x W1,000 x D730 mm H250 x W1,400 x D730 mm H250 x W1,400 x D730 mm H250 x W1,400 x D730 mm
Pipe Connection (Liquid) Ø6.35 mm (Ø1/4 inch) Ø6.35 mm (Ø1/4 inch) Ø6.35 mm (Ø1/4 inch) Ø6.35 mm (Ø1/4 inch) Ø6.35 mm (Ø1/4 inch) Ø6.35 mm (Ø1/4 inch) Ø6.35 mm (Ø1/4 inch) Ø6.35 mm (Ø1/4 inch) Ø9.52 mm (Ø3/8 inch) Ø9.52 mm (Ø3/8 inch) Ø9.52 mm (Ø3/8 inch)
Pipe Connection (Gas) Ø12.7 mm (Ø1/2 inch) Ø12.7 mm (Ø1/2 inch) Ø12.7 mm (Ø1/2 inch) Ø12.7 mm (Ø1/2 inch) Ø12.7 mm (Ø1/2 inch) Ø12.7 mm (Ø1/2 inch) Ø12.7 mm (Ø1/2 inch) Ø12.7 mm (Ø1/2 inch) Ø15.88 mm (Ø5/8 inch) Ø15.88 mm (Ø5/8 inch) Ø15.88 mm (Ø5/8 inch)
Pipe Connection (Drain Piping) VP-20 VP-20 VP-20 VP-20 VP-20 VP-20 VP-20 VP-20 VP-20 VP-20 VP-20
Net Weight 26 kg 26 kg 26 kg 26 kg 26 kg 31 kg 31 kg 31 kg 40 kg 40 kg 40 kg

Documents

Combination

Case Studies

Features

Cooling/Heating kW (rated)

2.2/2.5

2.8/3.2

3.6/4.2

4.5/5.0

5.6/6.3

6.0/7.1

7.3/8.0

9.0/10.0

11.2/12.5

14.0/16.0

16.0/18.0

Cooling/Heating Btu/h (rated)

7,500/8,500

9,600/10,900

12,300/14,300

15,400/17,100

19,100/21,500

20,500/24,200

24,900/27,300

30,700/34,100

38,200/42,700

47,800/54,600

54,600/61,400

Model No.

S-22MF3E5AN

S-28MF3E5AN

S-36MF3E5AN

S-45MF3E5AN

S-56MF3E5AN

S-60MF3E5AN

S-73MF3E5AN

S-90MF3E5AN

S-112MF3E5AN

S-140MF3E5AN

S-160MF3E5AN

A New Level of Air Quality with nanoe X Generator Mark3

24-hour nanoe™ X Air Protection

nanoe™ X inhibits certain bacteria, viruses, pollens, allergens, mould, and hazardous substances contained in PM2.5. Providing effective deodorisation and improving the quality of your air. nanoe™ X functions in both cooling and fan modes, and is maintenance-free, helping you enjoy 24 hours of quality air while keeping your costs down.
24-hour nanoe™ X Air Protection

Higher Concentration, Even in Large Space

The amount of hydroxyl radicals generated increased 100 times, compared to the original nanoe™, which achieves greater effectiveness even in large spaces of 112 m².

Conditions of the simulation ・Room size: 112 m² ・Room height: 2.4 m ・Inspection model: 4-Way Cassette ・Position of IDU: Centre
Note: The result is based on the conditions for the simulation and it may differ from the concentration measured in an actual room. nanoe™ particles are extremely tiny in nano-meter size. They cannot be seen, so the concentration image is solely for illustrative purposes.

Higher Concentration, Even in Large Space

Effective at Eliminating Odours in Only 30 Minutes

The nanoe X Generator Mark3 reduces odours by as much as 1.8 levels* in just 30 minutes. This is half the time required to achieve the same effect compared to the conventional nanoe X Generator Mark 2.
*A 1.8 level decrease in odour intensity is equivalent to a reduction of 95% or more.
[Odour intensity] 5: Very strong odour, 4: Strong odour, 3: Easily detectable odour, 2: Weak, recognisable odour (cognitive threshold concentration), 1: Barely detectable odour (detection threshold concentration), 0: No odour

Note: The test result is obtained using a 4-Way Cassette. **Testing Overview: [Testing organisation] Panasonic Product Analysis Center [Test method] Verification in a test room (approx. 230 m³ (6.8 x 8.5 x 4.0 m)) using a 6-step odour intensity display method [Method of deodorisation] Operation of a CS-P80U6 equipped with a nanoe X Generator Mark2 and release of nanoe™ [Target] Adhered aging odour (nonenal) [Test Result] Odour intensity reduced by 1.8 in 60 minutes (L19YK032-01) ***Testing Overview: [Testing organisation] Panasonic Product Analysis Center [Test method] Verification in a test room (approx. 230 m³ (6.8 x 8.5 x 4.0 m)) using a 6-step odour intensity display method [Method of deodorisation] Operation of a CS-P160U6 equivalent tester equipped with a nanoe X Generator Mark3 and release of nanoe™ [Target] Adhered aging odour (nonenal) [Test Result] Odour intensity reduced by 1.8 in 30 minutes (R21HM003-0)
Effective at Eliminating Odours in Only 30 Minutes

Benefit from nanoe™ X Even with Long, Curved Ductwork

Combined with the strong static pressure, this model ensures pristine nanoe™ X air travels unaffected, even through multiple duct shapes at lengths of 10 meters, as well as making them ideal for use in larger spaces.
Benefit from nanoe™ X Even with Long, Curved Ductwork

Flexible Installation to Maximize the Use of Spaces

Industry-Leading Vertical Installation That Accommodates Even Limited Ceiling Heights

Our groundbreaking drain pan design delivers a ducted unit that can be mounted horizontally or vertically without the need for alterations*. Even when ceiling space for ductwork is limited, the slim design allows for discrete placement away from rooms for total installation flexibility.
*Please refer to Installation Manual for full details.
Industry-Leading Vertical Installation That Accommodates Even Limited Ceiling Heights

Compact Enough to Allow Ceiling Height to be Maintained

The indoor units have also been completely renewed, offering a 40 mm height reduction to only 250 mm* and a weight reduction of up to 10%, all while maintaining the same powerful 150 Pa. Its compact 250 mm-high body means it takes up less space behind the ceiling, allowing for a higher ceiling in rooms.
*Compared to the conventional model range.
Compact Enough to Allow Ceiling Height to be Maintained

Enables Air Conditioning Without Disturbing Quiet Spaces

Features a low sound pressure level of 20 dB(A)*, as quiet as that of rustling leaves. It is ideal for quiet and relaxing spaces, such as hotel lobbies and guest rooms, thanks to its superior quiet performance.
*For 2.2-4.5 kW type and the airflow rate in low mode.
Enables Air Conditioning Without Disturbing Quiet Spaces

ECONAVI Sensor

Providing outstanding energy-saving performance, Panasonic’s inverter VRF System can be connected to ECONAVI to detect when energy is being wasted. ECONAVI senses the presence or absence of people and the level of activity in each area of an office. When unnecessary heating or cooling is detected, indoor units are individually controlled to match office conditions for energy-saving operation.

1. Detection of the level of activity enables optimum power saving.
2. Sensor is remotely located to maximise the energy-saving effect.
ECONAVI Sensor

Flexible Installation

The Panasonic Mid Static Adaptive Ducted unit sits only 250 mm high. This market-leading height enables easy installation into compact ceiling spaces.
Slim & Compact Design

Optimal airflow set-up is possible depending on ducting design and conditions.
Note: Please refer to technical databook for detail.
Variable External Static Pressure Control (10-150 Pa)

The air inlet position is adjustable via a movable panel to allow both rear or bottom entry, depending on the duct installation.
Selectable Air Inlet Position

Using a high-lift drain pump, drain piping can be elevated up to 690 mm from the base of the unit.
More Powerful Drain Pump

An inspection port (450 x 450 mm or more) is required at the lower side of the indoor unit body (field supply).
Installation of Inspection Port Necessary