Model |
CS/CU-KU18YKYXF |
Tonnage Class |
T |
1.5 |
Cooling Capacity Standard [Min. - Max.] |
Btu/h |
17400 [7826 - 19140] |
W |
5100 [2295 - 5610] |
Heating Capacity Standard [Min. - Max.] |
Btu/h |
- |
W |
- |
ISEER |
- |
4.10 |
Annual Power Consumption |
kWh |
962.49 |
Star Rating |
★ |
3★ |
Electrical Data |
Voltage |
V-AC |
230 |
Phase |
Φ |
Single Phase |
Running Current |
A |
7.5 |
Power Input, Standard Cooling [Min. - Max.] |
W |
1635 [504 - 2207] |
Power Input, Standard Heating [Min. - Max.] |
W |
- |
Moisture Removal Rate |
l/h |
1.2 |
Pt/h |
2.5 |
Air Circulation (Indoor/Hi) |
mᵌ/min |
18.0 |
ftᵌ/min |
636 |
Dimensions of the Indoor Unit |
Length (L) |
cm |
107.00 |
Breadth (B) |
cm |
23.5 |
Height (H) |
cm |
29.0 |
Dimensions of the Outdoor Unit |
Length (L) |
cm |
78.0 |
Breadth (B) |
cm |
28.8 |
Height (H) |
cm |
54.2 |
Noise Level |
Indoor (H/L) |
[dB-A] |
47/39 |
Outdoor |
[dB-A] |
53 |
Net Weight |
IDU [ODU](kg) |
12 [25] |
IDU [ODU](lb) |
27 [55] |
Gross Weight |
IDU [ODU](kg) |
14 [29.5] |
IDU [ODU](lb) |
31 [65] |
Refrigerant |
- |
R-32 |
Operating Temp. Range |
°C |
16 ~ 52 |
Operating Volt. Range |
V |
145 - 285 |
Refrigerant Pipe Diameter |
Liquid Side |
cm |
Ø0.635 |
Gas Side |
cm |
Ø1.270 |
Pipe Extension |
Chargeless Pipe Length * |
m |
7.5 |
Maximum Pipe Length * |
m |
15 |
Maximum Elevation Length * |
m |
10 |
Additional Refrigerant Gas * |
g/m |
15 |
Power Supply Source |
Indoor |
Name and Address of the Manufacturer |
Panasonic Life Solutions India Private Limited 12th Floor, Ambience Tower, Ambience Island, NH-8, Gurgaon - 122002, Haryana, India |
Country of Origin |
India |
Name of the Commodity |
Split Air-Conditioner |
Net Quantity |
1U |
Contents of the Package |
Indoor Unit: 1N, Outdoor Unit: 1N, Remote: 1N, AAA Batteries: 2N, Assembly Manual: 1N |