Retail Sales Price: Panasonic Online Price: Buy SHOP NOW WHERE TO BUY Shop Bar Shop Bar Out of Stock at Panasonic Online false false false

K2 Type Wall Mounted

Add to WishlistRemove from Wishlist

NO ROOM TO ADD MORE PRODUCTS

The wishlist has already reached the maximum number of products

K2 Type Wall Mounted

Its compact size and stylish smooth design make it ideal for small offices

K2 Type Wall Mounted units boast a stylish design and are compact and lightweight, making them easy to install. Their quiet operation makes them ideal for small offices, hotel rooms, and hospital rooms.
  • R32
  • R410A
Zoom In
Zoom Out
Close

Features

Panasonic R32 Refrigerant Leak Detector

R32 being a mildly flammable refrigerant (category A2L), the design and installation of systems operating with R32 must comply with the relevant refrigerant safety regulations. Those regulations which apply to our R32 Mini-VRF systems and the unique “incorporated circulation air flow” method is “IEC 60335-2-40 (ed. 6.0) for safety and flammability.“
The restrictions imposed on the refrigerant charges in a system due to the flammability of R32 are more severe than those imposed by toxicity. Therefore, in standard applications using our R32 Mini-VRF systems, toxic concentrations cannot occur.
Panasonic R32 Refrigerant Leak Detector

Cooling/Heating kW (rated)

2.2/2.5

2.8/3.2

3.6/4.2

4.5/5.0

5.6/6.3

7.3/8.0

10.6/11.4

Cooling/Heating Btu/h (rated)

7,500/8,500

9,600/10,900

12,300/14,300

15,400/17,100

19,100/21,500

24,900/27,300

36,200/38,900

Model No.

S-22MK2E5B

S-28MK2E5B

S-36MK2E5B

S-45MK2E5B

S-56MK2E5B

S-73MK2E5B

S-106MK2E5B

Cools the Area Quickly

Powerful airflow instantly makes spaces comfortable and cool.
Note: This table shows values for the airflow rate in high mode.
Cools the Area Quickly

Auto Air Distribution

The air outlet angle is automatically adjusted for cooling and heating operations.
Auto Air Distribution

Washable Front Panel

The indoor unit’s front panel can be easily removed and washed for trouble-free maintenance.
Washable Front Panel

Smart Power Saving with IoT

Next-Generation Remote Control Solution Optimised for Usability, Whatever Your Needs

CONEX goes beyond simple remote control to combine sophistication with simplicity, offering IoT integration that connects directly to a variety of apps for next-generation solutions.
Next-Generation Remote Control Solution Optimised for Usability, Whatever Your Needs

Smart Management of Power Consumption

Using the Panasonic Comfort Cloud app enables the air conditioner to be controlled from anywhere with a mobile device. Thus, there is no need to worry if someone forgets to turn off the office air conditioner. The power consumption can also be monitored to help reduce electricity waste.

Note: CZ-CAPWFC1 External WLAN Adaptor is required per unit.

Smart Management of Power Consumption

Leading Control Options

Panasonic air conditioning systems allow flexible control options. Individual, centralised, Cloud control and WLAN control are all possible. Please consult with a Panasonic air conditioning specialist for advice as to which control solution best suits your system requirements.
Leading Control Options

Flexible Installation

With a compact indoor unit, a piping outlet is possible in the six directions of right, right rear, right bottom, left, left rear, and left bottom, making installation easier.
Flexible Installation Options

The Noise Reducing External Valve kit reduces the noise level of the expansion valve. (Optional accessory)

・ CZ-P56SVK2 for 22-56 type
・ CZ-P160SVK2 for 73*-106 type
*When the pipe diameter is (Liquid) Ø6.35- (Gas) Ø12.7, please use CZ-P56SVK2.
Noise Reducing External Valve Kit

Specs

S-22MK2E5B

Photo of S-22MK2E5B

S-28MK2E5B

Photo of S-28MK2E5B

S-36MK2E5B

Photo of S-36MK2E5B

S-45MK2E5B

Photo of S-45MK2E5B

S-56MK2E5B

Photo of S-56MK2E5B

S-73MK2E5B

Photo of S-73MK2E5B

S-106MK2E5B

Photo of S-106MK2E5B
  • R32R32
  • R410AR410A
  • DC motorDC motor

Closed discharge port when not in use

Lighter and smaller units make installation easy

Quiet operation

Smooth and durable design and washable front panel

Piping outlet in six directions

Air distribution is automatically altered depending on the operational mode of the unit

S-22MK2E5B S-28MK2E5B S-36MK2E5B S-45MK2E5B S-56MK2E5B S-73MK2E5B S-106MK2E5B
Power Source (50/60 Hz) 220/230/240 V, 1 phase - 50/60 Hz 220/230/240 V, 1 phase 220/230/240 V, 1 phase 220/230/240 V, 1 phase 220/230/240 V, 1 phase 220/230/240 V, 1 phase 220/230/240 V, 1 phase
Cooling Capacity 2.2 kW, 7,500 Btu/h 2.8 kW, 9,600 Btu/h 3.6 kW, 12,300 Btu/h 4.5 kW, 15,400 Btu/h 5.6 kW, 19,100 Btu/h 7.3 kW, 24,900 Btu/h 10.6 kW, 36,200 Btu/h
Heating Capacity 2.5 kW, 8,500 Btu/h 3.2 kW, 10,900 Btu/h 4.2 kW, 14,300 Btu/h 5.0 kW, 17,100 Btu/h 6.3 kW, 21,500 Btu/h 8.0 kW, 27,300 Btu/h 11.4 kW, 38,900 Btu/h
Power Input (Cooling) 0.025/0.025/0.025 kW 0.025/0.025/0.025 kW 0.030/0.030/0.030 kW 0.030/0.030/0.030 kW 0.035/0.0.35/0.035 kW 0.055/0.055/0.055 kW 0.080/0.080/0.080 kW
Power Input (Heating) 0.025/0.025/0.025 kW 0.025/0.025/0.025 kW 0.030/0.030/0.030 kW 0.030/0.030/0.030 kW 0.035/0.0.35/0.035 kW 0.055/0.055/0.055 kW 0.080/0.080/0.080 kW
Running Current (Cooling) 0.21 A 0.23 A 0.25 A 0.33/0.32/0.31 A 0.36/0.35/0.34 A 0.52/0.51/0.50 A 0.72/0.70/0.68 A
Running Current (Heating) 0.21 A 0.23 A 0.25 A 0.33/0.32/0.31 A 0.36/0.35/0.34 A 0.52/0.51/0.50 A 0.72/0.70/0.68 A
Fan Type Cross-Flow Fan Cross-Flow Fan Cross-Flow Fan Cross-Flow Fan Cross-Flow Fan Cross-Flow Fan Cross-Flow Fan
Fan Air Flow Rate (H/M/L) 540/450/390 m³/h, 150/125/108 L/s 570/498/390 m³/h, 158/138/108 L/s 654/540/390 m³/h, 181/150/108 L/s 870/750/600 m³/h, 242/208/167 L/s 960/840/720 m³/h, 267/233/200 L/s 1,170/1,020/840 m³/h, 325/283/233 L/s 1,290/1,110/900 m³/h, 358/308/250 L/s
Fan Motor Output 0.03 kW 0.03 kW 0.03 kW 0.054 kW 0.054 kW 0.054 kW 0.054 kW
Sound Power Level (H/M/L) 51/48/44 dB 52/49/44 dB 55/51/44 dB 53/50/48 dB 55/52/50 dB 62/59/55 dB 64/61/57 dB
Sound Pressure Level (H/M/L) 36/33/29 dB (A) 37/34/29 dB (A) 40/36/29 dB (A) 38/35/33 dB (A) 40/37/35 dB (A) 47/44/40 dB (A) 49/46/42 dB (A)
Dimension H290 x W870 x D214 mm H290 x W870 x D214 mm H290 x W870 x D214 mm H302 x W1,120 x D236 mm H302 x W1,120 x D236 mm H302 x W1,120 x D236 mm H302 x W1,120 x D236 mm
Pipe Connection (Liquid) Ø6.35 mm (Ø1/4 inch) Ø6.35 mm (Ø1/4 inch) Ø6.35 mm (Ø1/4 inch) Ø6.35 mm (Ø1/4 inch) Ø6.35 mm (Ø1/4 inch) Ø9.52 mm (Ø3/8 inch) Ø9.52 mm (Ø3/8 inch)
Pipe Connection (Gas) Ø12.7 mm (Ø1/2 inch) Ø12.7 mm (Ø1/2 inch) Ø12.7 mm (Ø1/2 inch) Ø12.7 mm (Ø1/2 inch) Ø12.7 mm (Ø1/2 inch) Ø15.88 mm (Ø5/8 inch) Ø15.88 mm (Ø5/8 inch)
Pipe Connection (Drain Piping) Ø18 mm Ø18 mm Ø18 mm Ø18 mm Ø18 mm Ø18 mm Ø18 mm
Net Weight 9 kg 9 kg 9 kg 13 kg 13 kg 14 kg 14 kg

Documents

Combination

Case Studies