Retail Sales Price: Panasonic Online Price: Buy SHOP NOW WHERE TO BUY Shop Bar Shop Bar Out of Stock at Panasonic Online false false false

2-Pipe Mini-VRF LZ Series

Add to WishlistRemove from Wishlist

NO ROOM TO ADD MORE PRODUCTS

The wishlist has already reached the maximum number of products

2-Pipe Mini-VRF LZ Series

For small-scale commercial and residential use

The Mini-VRF LZ Series is designed for light commercial and residential use with extraordinary energy-saving performance and a high external static pressure of 35 Pa.
  • R32 Refrigerant
  • Inverter
  • DRED ready
  • Heat Pump
Zoom In
Zoom Out
Close

Features

Panasonic R32 Refrigerant Leak Detector

R32 being a mildly flammable refrigerant (category A2L), the design and installation of systems operating with R32 must comply with the relevant refrigerant safety regulations. Those regulations which apply to our R32 Mini-VRF systems and the unique “incorporated circulation air flow” method is “IEC 60335-2-40 (ed. 6.0) for safety and flammability.“
The restrictions imposed on the refrigerant charges in a system due to the flammability of R32 are more severe than those imposed by toxicity. Therefore, in standard applications using our R32 Mini-VRF systems, toxic concentrations cannot occur.
Panasonic R32 Refrigerant Leak Detector

Cooling/Heating kW (rated)

12.1/12.5

12.1/12.5

14.0/16.0

14.0/16.0

15.5/16.5

15.5/16.5

22.4/25.0

28.0/28.0

Cooling/Heating Btu/h (rated)

41,300/42,700

41,300/42,700

47,800/54,600

47,800/54,600

52,900/56,300

52,900/56,300

76,500/85,300

95,600/95,600

Model No.

U-4LZ2E5

U-4LZ2E8

U-5LZ2E5

U-5LZ2E8

U-6LZ2E5

U-6LZ2E8

U-8LZ2E8

U-10LZ2E8

Extraordinary Energy-Saving Performance

Extraordinary Energy-Saving Performance
The operation efficiency has been improved using a highly efficient R32 refrigerant, a DC Inverter compressor, a DC motor, and a heat exchanger design.

Energy Savings Design

1. Panasonic’s inverter compressor to improve partial-load capacity.
2. 2 pieces of the printed circuit board for easy maintenance.
3. Large-size accumulator to maintain compressor reliability for extended max piping length.
4. DC fan motor for optimum air volume.
5. Newly designed fan blades to inhibit air turbulence and increase efficiency.
6. Redesigned heat exchanger & copper tubes to increase efficiency.
7. Centrifugal oil separator improves oil separation efficiency and reduces refrigerant pressure loss.
Energy Savings Design

Variable Evaporation Temperature (VET) for Energy Saving and Comfortable Air conditioning

The indoor and outdoor units work in tandem to control evaporation temperature, refrigerant volume, and airflow. This enables optimal air conditioning according to the number of people in the room and the indoor temperature, as well as energy savings and comfort.

Note: When fan speed is set to Auto.

Variable Evaporation Temperature (VET) for Energy Saving and Comfortable Air conditioning

Demand Response Ready

Simple Demand Response

Featuring inverter control technology, LZ2*** series systems are Demand Response Management (DRM) ready. With this control, power consumption at times of peak load can be set in three steps to deliver optimum performance. This helps to correspond with the local power management for reducing peak power consumption, and to reduce annual power consumption with minimal loss in comfort.
*Demand controller. Relay contact point: No voltage relay. **Current input is DC 24V 10mA Use a very small electric current contact point for the relay. ***LZ2 series require to purchase Demand Terminal Kit.
Simple Demand Response

Flexible Demand Response

To use this function with the LZ2 series, it is necessary to purchase the Demand Terminal Kit (CZ-CAPDC3) (sold separately), install it on the outdoor unit at the site, and perform the appropriate settings.
A maintenance remote controller for service and special connection wiring are required for setting up the outdoor unit after installation of the kit, please contact your dealer for details.
Flexible Demand Response

High Durability

Wide Operating Range

Cooling operation is possible even when the outdoor temperature is as low as -10°C DB or as high as 52°C DB. As for heating operation, it is possible even when the outdoor temperature is as low as -20°C WB. The remote controller temperature can be set from 18°C up to 30°C (cooling), 16°C up to 30°C (heating)*.
*Depending on the type of remote controller.
Note: Cooling/heating capacity depend on indoor/outdoor temperature. Please refer technical databook.
Wide Operating Range

Rust-resistant and Easy to Maintain

The anti-corrosion Blue Fin treatment of the heat exchanger provides greater resistance against corrosion. Panasonic also uses a copper tube condenser, which makes it easy to repair and maintain. All models are equipped with Blue Fin condenser.

Note: Selecting this unit does not completely eliminate the possibility of rust developing. For details concerning unit installation and maintenance, please consult an authorised dealer.

Rust-resistant and Easy to Maintain

Smart Power Saving with IoT

A Next-Generation Remote Control Solution Optimised for Usability, Whatever Your Needs

CONEX goes beyond simple remote control to combine sophistication with simplicity, offering IoT integration that connects directly to a variety of apps for next-generation solutions.
Note: A wireless remote controller is provided with the product.
A Next-Generation Remote Control Solution Optimised for Usability, Whatever Your Needs

Smart Management of Power Consumption

Using the Panasonic Comfort Cloud app enables the air conditioner to be controlled from anywhere with a mobile device. Thus, there is no need to worry if someone forgets to turn off the office air conditioner. The power consumption can also be monitored to help reduce electricity waste.
Note: CZ-CAPWFC1 External WLAN Adaptor or CZ-RTC6WBLW/6BLW are required per unit.
Smart Management of Power Consumption

Highly Flexible Installation and Design

・ Maximum total piping length 180 m (12.1/14.0/15.5 kW) / 300 m (22.4/28.0 kW)

・ Actual piping length 90 m (12.1/14.0/15.5 kW) / 100 m (22.4/28.0 kW)

・ Elevation difference of maximum 50 m in case of outdoor unit is higher than indoor unit.

・ Maximum 15 meters height difference between indoor units. 

・ Up to 13 indoor units connectable in case of 22.4/28.0 kW.

・ High external static pressure of 35 Pa.

・ Demand response is capable with additional demand terminal kit CZ-CAPDC3.

* In South Australia, demand response capability is legally required from April 2023.

Highly Flexible Installation and Design

Specs

U-4LZ2E5

Photo of U-4LZ2E5

U-4LZ2E8

Photo of U-4LZ2E8

U-5LZ2E5

Photo of U-5LZ2E5

U-5LZ2E8

Photo of U-5LZ2E8

U-6LZ2E5

Photo of U-6LZ2E5

U-6LZ2E8

Photo of U-6LZ2E8

U-8LZ2E8

Photo of U-8LZ2E8

U-10LZ2E8

Photo of U-10LZ2E8
  • R32 RefrigerantR32 Refrigerant
  • InverterInverter
  • DRED readyDRED ready
  • Heat PumpHeat Pump

High external static pressure 35 Pa

Wide operation range: Cooling: -10°C to 52°C DB, Heating at: -20°C to 18°C WB

Diversity ratio 50-150% (4/5/6/8 HP) / 20-150% (10 HP)

Actual piping length: 90 m (4/5/6 HP) / 100 m (8/10 HP)

Total piping length: 180 m (4/5/6 HP) / 300 m (8/10 HP)

System difference of elevation: 50 m (outdoor unit above) / 40 m (below)

U-4LZ2E5 U-4LZ2E8 U-5LZ2E5 U-5LZ2E8 U-6LZ2E5 U-6LZ2E8 U-8LZ2E8 U-10LZ2E8
Power Supply (50 Hz) 230/240 V, 1 phase 400/415 V, 3 phase 230/240 V, 1 phase 400/415 V, 3 phase 230/240 V, 1 phase 400/415 V, 3 phase 400/415 V, 3 phase 400/415 V, 3 phase
Voltage 230/240 V 400/415 V 230/240 V 400/415 V 230/240 V 400/415 V 400/415 V 400/415 V
Capacity (Cooling) 12.1 kW, 41,300 Btu/h 12.1 kW, 41,300 Btu/h 14.0 kW, 47,800 Btu/h 14.0 kW, 47,800 Btu/h 15.5 kW, 52,900 Btu/h 15.5 kW, 52,900 Btu/h 22.4 kW, 76,500 Btu/h 28.0 kW, 95,600 Btu/h
Capacity (Heating) 12.5 kW, 42,700 Btu/h 12.5 kW, 42,700 Btu/h 16.0 kW, 54,600 Btu/h 16.0 kW, 54,600 Btu/h 16.5 kW, 56,300 Btu/h 16.5 kW, 56,300 Btu/h 25.0 kW, 85,300 Btu/h 28.0 kW, 95,600 Btu/h
EER/COP (Cooling) 4.53 W/W 4.53 W/W 4.12 W/W 4.12 W/W 3.88 W/W 3.88 W/W 3.84 W/W 3.47 W/W
EER/COP (Heating) 5.27 W/W 5.27 W/W 4.71 W/W 4.71 W/W 4.42 W/W 4.42 W/W 4.30 W/W 4.47 W/W
Dimension H996 x W980 x D370 mm H996 x W980 x D370 mm H996 x W980 x D370 mm H996 x W980 x D370 mm H996 x W980 x D370 mm H996 x W980 x D370 mm H1,500 x W980 x D370 mm H1,500 x W980 x D370 mm
Net Weight 94 kg 94 kg 94 kg 94 kg 94 kg 94 kg 125 kg 126 kg
Electrical Rating (Cooling - Running Current) 12.80/12.20 A 4.15/4.00 A 16.20/15.50 A 5.23/5.04 A 17.70/18.00 A 6.12/5.89 A 9.25/8.91 A 12.5/12.1 A
Electrical Rating (Cooling - Power Input) 2.67 kW 2.67 kW 3.40 kW 3.40 kW 4.00 kW 4.00 kW 5.83 kW 8.07 kg
Electrical Rating (Heating - Running Current) 11.40/11.00 A 3.71/3.58 A 16.20/15.20 A 5.22/5.03 A 17.71/17.00 A 5.72/5.51 A 9.32/8.98 A 9.93/9.57 A
Electrical Rating (Heating - Power Input) 2.37 kW 2.37 kW 3.40 kW 3.40 kW 3.73 kW 3.73 kW 5.81 kW 6.26 kW
Starting Current 1 A 1 A 1 A 1 A 1 A 1 A 1 A 1 A
Air Flow Rate 4,140 m³/h, 1,150 L/s 4,140 m³/h, 1,150 L/s 4,320 m³/h, 1,200 L/s 4,320 m³/h, 1,200 L/s 4,440 m³/h, 1,233 L/s 4,440 m³/h, 1,233 L/s 9,480 m³/h, 2,633 L/s 10,020 m³/h, 2,783 L/s
Refrigerant Amount at Shipment R32 2.7 kg R32 2.7 kg R32 2.7 kg R32 2.7 kg R32 2.7 kg R32 2.7 kg R32 4.9 kg R32 5.1 kg
Piping Connection (Gas Pipe) Ø15.88 mm (Ø5/8 inch) Ø15.88 mm (Ø5/8 inch) Ø15.88 mm (Ø5/8 inch) Ø15.88 mm (Ø5/8 inch) Ø15.88 mm (Ø5/8 inch) Ø15.88 mm (Ø5/8 inch) Ø19.05 mm (Ø3/4 inch) Ø22.22 mm (Ø7/8 inch)
Piping Connection (Liquid Pipe) Ø9.52 mm (Ø3/8 inch) Ø9.52 mm (Ø3/8 inch) Ø9.52 mm (Ø3/8 inch) Ø9.52 mm (Ø3/8 inch) Ø9.52 mm (Ø3/8 inch) Ø9.52 mm (Ø3/8 inch) Ø9.52 mm (Ø3/8 inch) Ø9.52 mm (Ø3/8 inch)
Ambient Temperature Operating Range (Cooling) -10˚C (DB) ~ +52˚C (DB) -10˚C (DB) ~ +52˚C (DB) -10˚C (DB) ~ +52˚C (DB) -10˚C (DB) ~ +52˚C (DB) -10˚C (DB) ~ +52˚C (DB) -10˚C (DB) ~ +52˚C (DB) -10˚C (DB) ~ +52˚C (DB) -10˚C (DB) ~ +52˚C (DB)
Ambient Temperature Operating Range (Heating) -20˚C (WB) ~ +18˚C (WB) -20˚C (WB) ~ +18˚C (WB) -20˚C (WB) ~ +18˚C (WB) -20˚C (WB) ~ +18˚C (WB) -20˚C (WB) ~ +18˚C (WB) -20˚C (WB) ~ +18˚C (WB) -20˚C (WB) ~ +18˚C (WB) -20˚C (WB) ~ +18˚C (WB)
Sound Pressure Level (Normal Mode) 52.0 dB (A) 52.0 dB (A) 53.0 dB (A) 53.0 dB (A) 54.0 dB (A) 54.0 dB (A) 59.0 dB (A) 60.0 dB (A)
Sound Pressure Level (Silent Mode 1/2/3/4) 49.0/47.0/45.0/45.0 dB (A) 49.0/47.0/45.0/45.0 dB (A) 50.0/48.0/46.0/45.0 dB (A) 50.0/48.0/46.0/45.0 dB (A) 51.0/49.0/47.0/45.0 dB (A) 51.0/49.0/47.0/45.0 dB (A) 56.0/54.0/52.0/50.0 dB (A) 57.0/55.0/53.0/50.0 dB (A)
Sound Power Level (Normal Mode) 69.0 dB 69.0 dB 70.0 dB 70.0 dB 72.0 dB 72.0 dB 72.0 dB 74.0 dB