Comfort Cooling/Heating All Year Round

Panasonic Standard Reverse Cycle Inverter RZ Series (AKR) features an anti-bacterial filter to ensure clean air is delivered throughout the space. POWERFUL Mode offers instant cooling with just a push of a button. AEROWINGS directs airflow further across the room. Enjoy cooling comfort while saving energy with Inverter technology, R32 refrigerant, and ECO Mode with A.I. Control. Stay connected with Panasonic Comfort Cloud App (optional network adaptor is required) to manage your air conditioners from one mobile device.
  • ANTI-BACTERIAL FILTER
  • Panasonic Comfort Cloud App
  • AEROWINGS
  • POWERFUL Mode
Zoom In
Zoom Out
Close
Standard Reverse Cycle Inverter RZ Series (AKR)

Features

Stay Warm/Cold Any Season All Year Long

Stay Warm/Cold Any Season All Year Long
The Panasonic RZ series wall split offers convenient comfort for every space, keeping you cool during the warm season and letting you enjoy warmth during the cooler season. Ensuring everyone's comfortable all year round.

Filters Bacteria and Viruses for Clean, Healthy Air

Filters Bacteria and Viruses for Clean, Healthy Air
The filter combines anti-bacterial¹, anti-virus², anti-allergen³ and anti-mould⁴ protection, ensuring that clean air is delivered to the room. It effectively deactivates up to 99% filter-captured bacteria, allergens and viruses, while also inhibiting mould growth.
¹ Test Organisation: Boken Quality Evaluation Institute •Test Report No: 100424591 and 100424592 •Bacteria: Staphylococcus aureus NBRC 12732 and Escherichia coli NBRC 3972
² Test Organisation: Osaka Prefectural Institute of Public Health •Test Report No: 313360397 •Virus: Influenza A (H3N2) Hong Kong
³ Test Organisation: Shinshu University •Allergen: Cedar Pollen Allergen Cry j1
⁴ Test Organisation: Boken Quality Evaluation Institute •Test Report No: 0003663 •Mould: Aspergillus niger ATCC 6275

Connect & Control Your Air Conditioners Anywhere, Anytime

Connect & Control Your Air Conditioners Anywhere, Anytime

Control multiple air conditioning units from anywhere, at home or away, with Panasonic Comfort Cloud App (requires optional network adaptor CZ-TACG1). Remotely access all air conditioning features, track and monitor usage of air conditioning units using comprehensive energy statistics and identify issues with error notifications for effortless troubleshooting, all just from one mobile device.

LEARN MORE

Advanced Smart Control with Voice Assistant Compatibility

Panasonic Comfort Cloud App also connects to leading voice assistants, granting you effortless control over your comfort. Optimise your air conditioning experience without lifting a finger – simply give a voice command to adjust settings and create the perfect comfort for your home.
Advanced Smart Control with Voice Assistant Compatibility

Intelligently Balances Energy Savings and Comfort

Intelligently Balances Energy Savings and Comfort

Every space has a different temperature and it varies throughout the day. ECO Mode with Artificial Intelligence (A.I.) Control learns and judges the optimal ECO level to maximise energy savings up to 20%* while providing consistent cooling comfort.

LEARN MORE

*Comparison of ECO mode & normal mode by using 3.5kW Inverter Model. Not applicable for multi-split systems.

Wide Cooling Capacity Range

With indoor cooling capacity range up to 9.5kW, Panasonic RZ series air conditioners offers the flexibility to scale cooling operation according to different needs and preferences, even for large spaces.
Wide Cooling Capacity Range

Comfort Cooling Environment for Your Needs

Faster and Further Airflow with AEROWINGS

AEROWINGS concentrates cool air for further and faster airflow across the room up to 25 meters* using 2 flaps. The sub-flap compresses and concentrates cool air, while the outer flap helps to deliver airflow further.
*Applicable to CS-RZ95AKR only.
Faster and Further Airflow with AEROWINGS

Instant Powerful Cooling with a Push of a Button

POWERFUL Mode will run both the compressor and indoor fan at super high speed, so you get to enjoy instant powerful cooling.
Instant Powerful Cooling with a Push of a Button

Calm and Peaceful Environment with Quiet Mode

Loud noises can be bothersome. Switch on Quiet mode to reduce the noise level of the indoor unit. In Quiet mode, the fan speed is reduced to minimum. This mode is ideal when you require a quiet, peaceful environment, during rest time or study.
Calm and Peaceful Environment with Quiet Mode

Sleep Better at Night

A comfortable environment is essential for healthy sleep. Our body’s temperature decreases while we sleep, thus less cooling is required. Sleep mode offers ambient temperature by automatically shifting the set temperature during sleeping time.
Sleep Better at Night

Built Tough to Last

Harsh coastal environments, with salty air, dust, wind, and rain, can damage and reduce the performance of the outdoor unit. Panasonic units are built to endure these elements, having undergone rigorous durability testing in extreme temperatures, high humidity, and low temperatures to ensure they continue to operate flawlessly. Enjoy continuous comfort regardless of climate.
Built Tough to Last

Robust Design and Long Term Endurance

1 Corrosion-Resistant Blue Fin Condenser

All Panasonic outdoor units feature Blue Fin coating, which protects the condenser from corrosion caused by air, water, and other corrosive elements.
Corrosion-Resistant Blue Fin Condenser

2 Better Heat Transfer with Copper Tube Condenser

Panasonic outdoor units feature copper tube condensers, offering higher cooling capacity for efficient heat transfer.
Better Heat Transfer with Copper Tube Condenser

3 Corrosion-Resistant Outdoor Coating

Durable outdoor unit with a multi-layered, corrosion-resistant coating shrugs off rain and salty water for long-lasting performance.
Corrosion-Resistant Outdoor Coating

4 Water-Resistant PCB

Contact sections on the PCB feature a special resin coating, protecting them from damage caused by water droplets.
Water-Resistant PCB

Convenient Control at Your Fingertips

Wireless Remote Controller

The handheld wireless remote controller is easy to use, with commonly used functions for quick access.
*A wireless remote controller is included in the same package as the indoor unit. Product design may vary by models.
Wireless Remote Controller

Optional Wired Remote Controller

The optional wired remote controller provides a large display for improved visibility and a vast range of information to ease operations.
Optional Wired Remote Controller

Range

Model

Cooling Capacity

2.5 kW

3.5 kW

4.2 kW

5.0 kW

6.0 kW

7.1 kW

8.0 kW

9.5 kW

8,530 Btu/h

11,900 Btu/h

14,300 Btu/h

17,100 Btu/h

20,500 Btu/h

24,200 Btu/h

27,300 Btu/h

32,400 Btu/h

Heating Capacity

3.0 kW

4.0 kW

5.0 kW

6.0 kW

6.5 kW

8.0 kW

9.0 kW

10.3 kW

10,200 Btu/h

13,600 Btu/h

17,100 Btu/h

20,500 Btu/h

22,200 Btu/h

27,300 Btu/h

30,700 Btu/h

35,100 Btu/h

Indoor Unit

CS-RZ25AKRW

CS-RZ35AKRW

CS-RZ42AKRW

CS-RZ50AKRW

CS-RZ60AKRW

CS-RZ71AKRW

CS-RZ80YKR

CS-RZ95AKR

Outdoor Unit

CU-RZ25AKR

CU-RZ35AKR

CU-RZ42AKR

CU-RZ50AKR

CU-RZ60AKR

CU-RZ71AKR

CU-RZ80YKR

CU-RZ95AKR

Specs

CS_CU-RZ25AKR

Photo of CS_CU-RZ25AKR

CS_CU-RZ35AKR

Photo of CS_CU-RZ35AKR

CS_CU-RZ42AKR

Photo of CS_CU-RZ42AKR

CS_CU-RZ50AKR

Photo of CS_CU-RZ50AKR

CS_CU-RZ60AKR

Photo of CS_CU-RZ60AKR

CS_CU-RZ71AKR

Photo of CS_CU-RZ71AKR

CS_CU-RZ80YKR

Photo of CS_CU-RZ80YKR

CS_CU-RZ95AKR

Photo of CS_CU-RZ95AKR
  • ANTI-BACTERIAL FILTERANTI-BACTERIAL FILTER
  • AEROWINGSAEROWINGS
  • POWERFUL ModePOWERFUL Mode
  • ECO Mode with A.I. ControlECO Mode with A.I. Control
  • InverterInverter
  • R32 RefrigerantR32 Refrigerant
  • Quiet ModeQuiet Mode
  • Sleep ModeSleep Mode
  • DRED readyDRED ready

Anti-bacterial filter delivers quality indoor air to your spaces

Manage your air conditioner using your mobile device with Comfort Cloud App (Optional network adaptor is required)

AEROWINGS concentrates cool air for further and faster airflow across the room

POWERFUL Mode lets you enjoy instant powerful cooling during start-up

ECO Mode with A.I. control intelligently balances energy savings and comfort

Energy efficiency with Inverter technology and R32 refrigerant

CS_CU-RZ25AKR CS_CU-RZ35AKR CS_CU-RZ42AKR CS_CU-RZ50AKR CS_CU-RZ60AKR CS_CU-RZ71AKR CS_CU-RZ80YKR CS_CU-RZ95AKR
Indoor Unit CS-RZ25AKRW CS-RZ35AKRW CS-RZ42AKRW CS-RZ50AKRW CS-RZ60AKRW CS-RZ71AKRW CS-RZ80YKR CS-RZ95AKR
Outdoor Unit CU-RZ25AKR CU-RZ35AKR CU-RZ42AKR CU-RZ50AKR CU-RZ60AKR CU-RZ71AKR CU-RZ80YKR CU-RZ95AKR
Cooling Capacity (min-max) (kW) 2.50 (0.95-3.70) kW 3.50 (1.00-4.20) kW 4.20 (1.15-5.10) kW 5.00 (1.15-6.10) kW 6.00 (1.25-6.90) kW 7.10 (1.70-8.50) kW 8.00 (2.30-9.00) kW 9.50 (2.80-11.20) kW
Heating Capacity (min-max) (kW) 3.00 (0.90-4.40) kW 4.00 (0.90-5.70) kW 5.00 (0.90-6.80) kW 6.00 (0.98-7.70) kW 6.50 (0.98-8.20) kW 8.00 (1.70-10.60) kW 9.00 (2.20-11.60) kW 10.30 (2.40-12.30) kW
Cooling Capacity (min-max) (Btu/h) 8,530 (3,240-12,600) Btu/h 11,900 (3,410-14,300) Btu/h 14,300 (3,920-17,400) Btu/h 17,100 (3,920-20,800) Btu/h 20,500 (4,260-23,500) Btu/h 24,200 (5,800-29,000) Btu/h 27,300 (7,840-30,700) Btu/h 32,400 (9,550-38,200) Btu/h
Heating Capacity (min-max) (Btu/h) 10,200 (3,070-15,000) Btu/h 13,600 (3,070-19,400) Btu/h 17,100 (3,070-23,200) Btu/h 20,500 (3,340-26,300) Btu/h 22,200 (3,340-28,000) Btu/h 27,300 (5,800-36,100) Btu/h 30,700 (7,500-39,600) Btu/h 35,100 (8,180-41,900) Btu/h
Cooling Indoor Air Flow (L/s) 188 L/s 193 L/s 193 L/s 208 L/s 328 L/s 352 L/s 367 L/s 407 L/s
Heating Indoor Air Flow (L/s) 200 L/s 202 L/s 202 L/s 228 L/s 339 L/s 367 L/s 377 L/s 420 L/s
Dehumid (L/h) 1.50 L/h 2.00 L/h 2.40 L/h 2.80 L/h 3.30 L/h 4.10 L/h 4.70 L/h 5.00 L/h
Cooling Running Current (A) 2.55 A 3.60 A 5.00 A 6.50 A 7.90 A 8.80 A 10.10 A 12.00 A
Heating Running Current (A) 2.90 A 3.85 A 5.45 A 7.30 A 8.00 A 8.90 A 9.80 A 11.70 A
Max Current (A) 6.30 A 7.20 A 8.90 A 11.00 A 11.60 A 14.80 A 15.00 A 16.60 A
Cooling Power Input (min-max) (kW) 0.58 (0.20-1.20) kW 0.82 (0.21-1.29) kW 1.18 (0.22-1.64) kW 1.51 (0.24-2.10) kW 1.85 (0.35-2.20) kW 2.06 (0.45-2.90) kW 2.39 (0.46-3.03) kW 2.84 (0.50-3.50) kW
Heating Power Input (min-max) (kW) 0.65 (0.19-1.29) kW 0.87 (0.19-1.65) kW 1.30 (0.20-2.04) kW 1.72 (0.26-2.50) kW 1.89 (0.26-2.64) kW 2.09 (0.40-3.30) kW 2.34 (0.43-3.42) kW 2.78 (0.44-3.50) kW
Cooling AEER/EER 4.28 W/W / 4.31 W/W 4.22 W/W / 4.27 W/W 3.53 W/W / 3.56 W/W 3.29 W/W / 3.31 W/W 3.23 W/W / 3.24 W/W 3.43 W/W / 3.45 W/W 3.34 W/W / 3.35 W/W 3.33 W/W / 3.35 W/W
Heating ACOP/COP 4.57 W/W / 4.62 W/W 4.55 W/W / 4.60 W/W 3.82 W/W / 3.85 W/W 3.47 W/W / 3.49 W/W 3.42 W/W / 3.44 W/W 3.81 W/W / 3.83 W/W 3.83 W/W / 3.85 W/W 3.69 W/W / 3.71 W/W
Star Rating - Cooling (Hot Climate) 4.5 TCSPF 4.5 TCSPF 3.5 TCSPF 3.5 TCSPF 3.5 TCSPF 3.5 TCSPF 3.5 TCSPF 3.5 TCSPF
Star Rating - Cooling (Average Climate) 4.0 TCSPF 4.5 TCSPF 3.5 TCSPF 3.5 TCSPF 3.5 TCSPF 3.5 TCSPF 3.5 TCSPF 3.0 TCSPF
Star Rating - Cooling (Cold Climate) 4.0 TCSPF 4.5 TCSPF 3.5 TCSPF 3.5 TCSPF 3.5 TCSPF 3.5 TCSPF 3.5 TCSPF 3.5 TCSPF
Star Rating - Heating (Hot Climate) 3.5 HSPF 3.5 HSPF 3.5 HSPF 3.0 HSPF 3.5 HSPF 3.5 HSPF 3.5 HSPF 3.0 HSPF
Star Rating - Heating (Average Climate) 3.0 HSPF 3.0 HSPF 2.5 HSPF 2.5 HSPF 3.0 HSPF 2.5 HSPF 2.5 HSPF 2.5 HSPF
Star Rating - Heating (Cold Climate) 2.5 HSPF 2.5 HSPF 2.0 HSPF 2.0 HSPF 2.0 HSPF 2.0 HSPF 2.0 HSPF 2.0 HSPF
Indoor Unit Sound Pressure Noise Level (Cooling) (H / L / Q-Lo) 40/25/19 dB(A) *Sound pressure level specification is measured according to JIS C9612. 44/26/19 dB(A) *Sound pressure level specification is measured according to JIS C9612. 44/31/28 dB(A) *Sound pressure level specification is measured according to JIS C9612. 44/34/28 dB(A) *Sound pressure level specification is measured according to JIS C9612. 47/36/33 dB(A) *Sound pressure level specification is measured according to JIS C9612. 49/37/34 dB(A) *Sound pressure level specification is measured according to JIS C9612. 51/38/35 dB(A) *Sound pressure level specification is measured according to JIS C9612. 53/40/38 dB(A) *Sound pressure level specification is measured according to JIS C9612.
Indoor Unit Sound Pressure Noise Level (Heating) (H / L / Q-Lo) 40/27/21 dB(A) *Sound pressure level specification is measured according to JIS C9612. 44/29/22 dB(A) *Sound pressure level specification is measured according to JIS C9612. 44/32/28 dB(A) *Sound pressure level specification is measured according to JIS C9612. 44/33/29 dB(A) *Sound pressure level specification is measured according to JIS C9612. 48/36/33 dB(A) *Sound pressure level specification is measured according to JIS C9612. 49/37/34 dB(A) *Sound pressure level specification is measured according to JIS C9612. 50/38/35 dB(A) *Sound pressure level specification is measured according to JIS C9612. 52/40/35 dB(A) *Sound pressure level specification is measured according to JIS C9612.
Indoor Unit Sound Power Noise Level (Cooling) (H / L / Q-Lo) 56/41/35 dB(A) 60/42/35 dB(A) 60/47/44 dB(A) 60/50/44 dB(A) 63/52/49 dB(A) 65/53/50 dB(A) 67/54/51 dB(A) 69/56/54 dB(A)
Indoor Unit Sound Power Noise Level (Heating) (H / L / Q-Lo) 56/43/37 dB(A) 60/45/38 dB(A) 60/48/44 dB(A) 60/49/45 dB(A) 64/52/49 dB(A) 65/53/50 dB(A) 66/54/51 dB(A) 68/56/51 dB(A)
Indoor Unit Dimensions (H x W x D) (mm) 290 mm x 779 mm x 209 mm 290 mm x 779 mm x 209 mm 290 mm x 779 mm x 209 mm 290 mm x 779 mm x 209 mm 295 mm x 1,040 mm x 244 mm 295 mm x 1,040 mm x 244 mm 295 mm x 1,040 mm x 244 mm 309 mm x 1,212 mm x 269 mm
Indoor Unit Net Weight 8 kg 8 kg 8 kg 8 kg 12 kg 13 kg 13 kg 17 kg
Outdoor Unit Sound Pressure Noise Level (Cooling) (H / Q-Lo) 48/43 dB(A) *Sound pressure level specification is measured according to JIS C9612. 49/44 dB(A) *Sound pressure level specification is measured according to JIS C9612. 49/44 dB(A) *Sound pressure level specification is measured according to JIS C9612. 48/43 dB(A) *Sound pressure level specification is measured according to JIS C9612. 49/44 dB(A) *Sound pressure level specification is measured according to JIS C9612. 54/49 dB(A) *Sound pressure level specification is measured according to JIS C9612. 55/50 dB(A) *Sound pressure level specification is measured according to JIS C9612. 55/50 dB(A) *Sound pressure level specification is measured according to JIS C9612.
Outdoor Unit Sound Pressure Noise Level (Heating) (H / Q-Lo) 49/44 dB(A) *Sound pressure level specification is measured according to JIS C9612. 50/45 dB(A) *Sound pressure level specification is measured according to JIS C9612. 51/46 dB(A) *Sound pressure level specification is measured according to JIS C9612. 49/44 dB(A) *Sound pressure level specification is measured according to JIS C9612. 51/46 dB(A) *Sound pressure level specification is measured according to JIS C9612. 54/49 dB(A) *Sound pressure level specification is measured according to JIS C9612. 55/50 dB(A) *Sound pressure level specification is measured according to JIS C9612. 55/50 dB(A) *Sound pressure level specification is measured according to JIS C9612.
Outdoor Unit Sound Power Noise Level (Cooling) (H / Q-Lo) 63/58 dB(A) 64/59 dB(A) 64/59 dB(A) 63/58 dB(A) 64/59 dB(A) 68/63 dB(A) 69/64 dB(A) 69/64 dB(A)
Outdoor Unit Sound Power Noise Level (Heating) (H / Q-Lo) 64/59 dB(A) 65/60 dB(A) 66/61 dB(A) 64/59 dB(A) 66/61 dB(A) 68/63 dB(A) 69/64 dB(A) 69/64 dB(A)
Outdoor Unit Dimensions (H x W x D) 542 mm x 780 mm x 289 mm 542 mm x 780 mm x 289 mm 542 mm x 780 mm x 289 mm 619 mm x 824 mm x 299 mm 619 mm x 824 mm x 299 mm 695 mm x 875 mm x 320 mm 795 mm x 875 mm x 320 mm 795 mm x 875 mm x 320 mm
Outdoor Unit Net Weight 25 kg 31 kg 31 kg 35 kg 35 kg 45 kg 51 kg 55 kg
Refrigerant Type R32 R32 R32 R32 R32 R32 R32 R32
Refrigerant Pipe Diameter (Liquid Side) ø 6.35 mm (1/4 inch) ø 6.35 mm (1/4 inch) ø 6.35 mm (1/4 inch) ø 6.35 mm (1/4 inch) ø 6.35 mm (1/4 inch) ø 6.35 mm (1/4 inch) ø 6.35 mm (1/4 inch) ø 6.35 mm (1/4 inch)
Refrigerant Pipe Diameter (Gas Side) ø 9.52 mm (3/8 inch) ø 9.52 mm (3/8 inch) ø 12.70 mm (1/2 inch) ø 12.70 mm (1/2 inch) ø 12.70 mm (1/2 inch) ø 15.88 mm (5/8 inch) ø 15.88 mm (5/8 inch) ø 15.88 mm (5/8 inch)
Pipe Extension Length (min-max) 3 m ~ 20 m 3 m ~ 20 m 3 m ~ 20 m 3 m ~ 30 m 3 m ~ 30 m 3 m ~ 30 m 3 m ~ 30 m 3 m ~ 30 m
Maximum Elevation Length 15 m 15 m 15 m 15 m 15 m 20 m 20 m 20 m
Pipe Length for Additional Refrigerant Gas 7.50 m 7.50 m 7.50 m 10 m 10 m 10 m 10 m 10 m
Pipe Extension (Additional Refrigerant Gas*) 10 g/m 10 g/m 10 g/m 15 g/m 15 g/m 25 g/m 25 g/m 25 g/m
Power Supply Outdoor Outdoor Outdoor Outdoor Outdoor Outdoor Outdoor Outdoor
Outdoor Unit Operating Range (Cooling) -10°C ~ +46°C -10°C ~ +46°C -10°C ~ +46°C -10°C ~ +46°C -10°C ~ +46°C -10°C ~ +46°C -10°C ~ +46°C -10°C ~ +46°C
Outdoor Unit Operating Range (Heating) -15°C ~ +24°C -15°C ~ +24°C -15°C ~ +24°C -15°C ~ +24°C -15°C ~ +24°C -15°C ~ +24°C -15°C ~ +24°C -15°C ~ +24°C
POWERFUL Mode Yes Yes Yes Yes Yes Yes Yes Yes
ECO Mode with A.I. Yes Yes Yes Yes Yes Yes Yes Yes
Inverter Control Yes Yes Yes Yes Yes Yes Yes Yes
Sleep Mode Yes Yes Yes Yes Yes Yes Yes Yes
Quiet Mode Yes Yes Yes Yes Yes Yes Yes Yes
Fan Mode Yes Yes Yes Yes Yes Yes Yes Yes
Soft Dry Operation Mode Yes Yes Yes Yes Yes Yes Yes Yes
Hot Start Control Yes Yes Yes Yes Yes Yes Yes Yes
Auto Changeover (Inverter) Yes Yes Yes Yes Yes Yes Yes Yes
Personal Airflow Creation No No No No Yes Yes Yes Yes
Manual Horizontal Airflow Direction Control Yes Yes Yes Yes No No No No
Airflow Direction Control (Up & Down) Yes Yes Yes Yes No No No No
Anti-Bacterial Filter Yes Yes Yes Yes Yes Yes Yes Yes
Odour Removing Function Yes Yes Yes Yes Yes Yes Yes Yes
Removable Washable Panel Yes Yes Yes Yes Yes Yes Yes Yes
24-Hour Dual ON & OFF Real Setting Timer Yes Yes Yes Yes Yes Yes Yes Yes
Demand Response Enabling Device (DRED) Yes Yes Yes Yes Yes Yes Yes Yes
LCD Wireless Remote Control Yes Yes Yes Yes Yes Yes Yes Yes
Wi-Fi Optional (Network adaptor required) Optional (Network adaptor required) Optional (Network adaptor required) Optional (Network adaptor required) Optional (Network adaptor required) Optional (Network adaptor required) Optional (Network adaptor required) Optional (Network adaptor required)
Wired Remote Control Yes (Optional) Yes (Optional) Yes (Optional) Yes (Optional) Yes (Optional) Yes (Optional) Yes (Optional) Yes (Optional)
Random Auto Restart Yes (32 Restart Patterns) Yes (32 Restart Patterns) Yes (32 Restart Patterns) Yes (32 Restart Patterns) Yes (32 Restart Patterns) Yes (32 Restart Patterns) Yes (32 Restart Patterns) Yes (32 Restart Patterns)
Blue Fin Condenser Yes Yes Yes Yes Yes Yes Yes Yes
Long Piping (max.) 20 m 20 m 20 m 30 m 30 m 30 m 30 m 30 m
Top Panel Maintenance Access Yes Yes Yes Yes Yes Yes Yes Yes
Self-Diagnostic Function Yes Yes Yes Yes Yes Yes Yes Yes
Note Please read the Installation Instructions carefully before installing the unit, and the Operating Instructions before using it. Specifications are subject to change without prior notice. Please read the Installation Instructions carefully before installing the unit, and the Operating Instructions before using it. Specifications are subject to change without prior notice. Please read the Installation Instructions carefully before installing the unit, and the Operating Instructions before using it. Specifications are subject to change without prior notice. Please read the Installation Instructions carefully before installing the unit, and the Operating Instructions before using it. Specifications are subject to change without prior notice. Please read the Installation Instructions carefully before installing the unit, and the Operating Instructions before using it. Specifications are subject to change without prior notice. Please read the Installation Instructions carefully before installing the unit, and the Operating Instructions before using it. Specifications are subject to change without prior notice. Please read the Installation Instructions carefully before installing the unit, and the Operating Instructions before using it. Specifications are subject to change without prior notice. Please read the Installation Instructions carefully before installing the unit, and the Operating Instructions before using it. Specifications are subject to change without prior notice.