Pure Hydrogen Fuel Cell Generator

Photo of Pure Hydrogen Fuel Cell Generator

Product name

  • Pure Hydrogen Fuel Cell Generator ”H2 KIBOU”

Type of fuel cell

  • Polymer Electrolyte Fuel Cell (PEFC)

Model number

  • FC-H99PGD1P

Year and month of release

  • October 2024 (planned)

Design panel

  • Optional product (separately sold)

Configuration

  • Cogeneration system (external water-cooling system)

Basic performance

  • Output

    • Power

      • 10kW max.
        Adjustable in 1kW increments between 4 and 10kW
    • Voltage

      • DC 380-495V*⁸
        (Fixed Voltage)
  • Power consumption

    • During startup

      • 300±90W
    • Freezing prevention

      • 583W
  • Efficiency

    • Power generation (DC)

      • LHV: 57%, HHV: 48.1%
    • Heat recovery

      • LHV: 47%, HHV: 39.7%
  • Hydrogen

    • Consumption

      • 97.5NL/min ≈ 6N㎥/h
        103.7NL/min (Max)
    • Supply pressure

      • 50±20kPa
  • Exhaust heat

    • Output

      • 8248W
    • Water-cooling device

      • Water-cooling equipment is required (external procurement)
    • Supporting cogeneration

      • Hot water storage unit (external procurement)
  • Time

    • Startup

      • 30sec (approx. 40sec to achieve the rating)
    • Continuous power generation

      • 168hours (7days)
  • Dimensions

    • Main unit

      • W900mm x D865mm x H1787mm
        W900mm x D898mm x H1787mm (with a design panel)
    • Main unit packaging

      • W957mm x D966mm x H1917mm
  • Weight

    • Main unit when dry

      • 340kg
        354kg (with a design panel)
    • Packaging when dry

      • 360kg
        (a design panel is 18kg)
  • Control

    • When up to 10 modules are connected*⁹

      • PH3 app (provided with PH3) (PH3 app is not required during EMS connection)
    • When up to 250 modules are connected (with PLC)*¹⁰

      • PH3 app (provided with PH3) (PH3 app is not required during EMS connection)

Installation conditions

  • Maximum altitude for installation

    • 1,000m
  • Maintenance space

    • Front maintenance: 600mm, Other: 10mm *11,12
  • Installation environment temperature

    • -15 to 40ºC

Maintenance

  • Periodical Maintenance

    • Required depending on cumulative hours of power generation
  • Overhaul (Whichever comes first)

    • Energization time 15years
      Cumulative hours of power generation 100,000H
      Cumulative start & stop cycle 4,500times

Note

  • *8 : The inverter is required conforming to the application note.
    *9 : The computer used to install the app must be provided by the customer. The computer and fuel cell unit must be connected via LAN.
    *10 : The computer and PLC used to install the app must be provided by the customer. The computer and PLC, as well as the PLC and fuel cell unit, must be connected via LAN (hub relay).
    *11 : On the side of the front face of the main unit, 400mm space is required to open the door.
    *12 : In case of attaching a design panel, 70mm space is required for left and right sides.
    The product described in this release is under development and its specifications are subject to change without prior notice.